Chapter 6 Service and Maintenance
352 OL-31086-01
Warning
Message
Type
Message
Cause/Remedy
Description
ID
ECT Timeout #
Set
ECT # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
No longer receiving
Event Control Table.
77200
ECT Timeout #
Clear
ECT fault cleared
77200
Memory Usage
Host
Set
Excessive
(stack/partition)
memory usage
Cause: Possible software
issue.
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.
SW exceeding
allowable memory
usage.
78000
Memory Usage
Host
Clear
Normal
(stack/partition)
memory usage
78000
Memory Usage
Secondary
Set
Excessive
(stack/partition)
memory usage
Cause: Possible software
issue.
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.
Software exceeding
allowable memory
usage.
79000
Memory Usage
Secondary
Clear
Normal
(stack/partition)
memory usage
79000
FPGA Code
Version
Set
FPGA newer
than SW,
Supported=AAA,
Running=BBB
Cause: FPGA version is
incompatible with the
software.
Remedy: Select alternate
FPGA, software
versions, reset unit,
notify Cisco customer
support if problem
persists.
FPGA version is
incompatible with
currently operating
software. You may
encounter operational
difficulties
80000
FPGA Code
Version
Clear
FPGA code ver
OK
80000