Installation Guide
OL-31086-01 339
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
MIP Output
Spacing (D9854
with SFN only)
Set
MIP Output
Spacing Erratic -
Data lost
Cause: Current
transport rate
exceeds the
configured rate for
ASI output.
Remedy: Increase
output rate.
Contact the uplink
to verify the
expected bit rate
settings.
Severe
differences in
the MIP
packets
detected on the
input versus
the MIP
packets
transmitted to
the ASI output.
Minor
40500
MIP Output
Spacing (D9854
with SFN only)
Clear
MIP Output
Spacing Stable
–
–
Minor
40500
FEC USB Flash
(D9854-I only)
Set
FEC USB Option
not installed
Cause: FEC USB
connector not
installed.
Remedy: Ensure
that the FEC USB
connector and
FLASH module
are installed.
FEC USB
option not
detected.
Major
92300
FEC USB Flash
(D9854-I only)
Set
FEC USB Flash not
found
Cause: FEC USB
FLASH not
installed. This
may occur in
Production if the
USB module is not
inserted before the
first power on the
board.
Remedy: Ensure
that the FEC USB
connector and
FLASH module
are installed.
FEC USB
FLASH mount
failed.
Major
92300
FEC USB Flash
(D9854-I only)
Clear
FEC USB Flash
OK
–
–
Major
92300