Installation Guide
Chapter 6 Service and Maintenance
338 OL-31086-01
Alarm
Message
Type
Message
Cause/Remedy
Description
Severity
ID
FPGA status
Set
FPGA Init went
LOW (CRC error)
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Set
FPGA Done failed
to go high
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Set
SW ver outside
upper or lower
limit
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Set
FPGA ID does not
match FPGA
DESIGNATION
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Set
FPGA ID does not
match HW FPGA
ID
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.
FPGA setup
failure or the
FPGA binary
identity does
not match the
FPGA registers.
Major
39000
FPGA status
Clear
FPGA loaded
successfully and
reset
–
–
Major
39000