Installation Guide

Configuring Transport Stream Information
OL-31086-01 253
Typical set up for Digital Program Mapping (DPM)
1 Verify that you are receiving a valid signal and that you have set up the channels
that you want to pass, drop, or map.
2 From the user interface of the D9854/D9854-I, choose Transport Stream > ASI
Output or MPEG over IP Output.
3 From the Output Mode drop-down list, choose Full DPM Control.
4 If necessary, from the Descrambled drop-down list, choose whether the program
is to be scrambled or descrambled for downstream viewing or monitoring.
5 Click Apply.
6 Click Transport Stream > Digital Program Mapping for ASI Output or MPEG
over IP Output. The ASI or MPEGoIP Digital Program Mapping page is
displayed.
7 Click Resynchronize All. This copies the input services PIDs to the remapped
output service PIDs.
8 Click the radio button of the PE containing the channel you want to configure
and click Edit. The DPM PE PID MAP dialog box is displayed.
9 Click Add Row.
10 From the Action drop-down list, choose Drop or Map.
11 Choose the input to output channel mapping from the Category drop-down list.
Video and PCR can be output on the same PID or different PIDs. If output on the
same PID, they will appear identical to the input.
12 Click Save.
13 Click OK.
14 In the DPM General Setting area, set the following parameters:
Parameter
Description
Remapping Mode
Svc ID & PID
Duplication Method
Pkt Copy
Unreferenced Content
Drop
Service ID Output
Valid Ch/All Ch
PSI Table Output Option
Ctl By Table
PSI Regeneration Option
Always/As Needed
15 Click Table Options. The DPM Table Options (ASI) dialog box is displayed.
16 Set the following parameters:
Parameter
Description
PAT
Regen