Cisco 2-Channel SFP-Based Wavelength Converter Installation Note Revised: January 19, 2012 Product Number: WDM-SFP-2CH-CONV= This document provides installation instructions for the Cisco 2-Channel SFP-Based Wavelength Converter.
Overview Overview The Cisco 2-Channel SFP-Based Wavelength Converter is a stand-alone dual-channel CWDM converter device. (See Figure 1.) The Cisco 2-Channel SFP-Based Wavelength Converter can accommodate protocols at any data rate between 125 Mbs and 2.67 Mbs. Any combination of SFP transceivers can be used in the converter.
Overview Table 1 2-Channel SFP-Based Wavelength Converter LED Descriptions (continued) LED Status Description EQPT1and EQPT2 RX Off SFP transceiver is not detected in the Equipment 1 or in the Equipment 2 socket. Green SFP transceiver signal is detected. Flashing Green Loss of lock detected in SFP installed in the Equipment 1 or Equipment 2 socket. Red Equipment 1 or Equipment 2 SFP receiver is not detecting a signal.
Safety Overview Safety Overview Throughout this publication, safety warnings appear in procedures that, if performed incorrectly, can harm you. A warning symbol precedes each warning statement. Statement 1071—Warning Definition Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury.
Safety Overview Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
Safety Overview Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.
Safety Overview Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo.
Safety Overview Cisco 2-Channel SFP-Based Wavelength Converter Installation Note 8 78-16648-01
Safety Overview Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 Warning Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 Warning Class 1 laser product. Statement 1008 Warning Use of controls, adjustments, or performing procedures other than those specified may result in hazardous radiation exposure.
Installing the 2-Channel SFP-Based Wavelength Converter Installing the 2-Channel SFP-Based Wavelength Converter The following sections provide installation procedures for the 2-Channel SFP-Based Wavelength Converter: • Required Tools, page 10 • Installing the 2-Slot Chassis (CWDM-CHASSIS-2=), page 10 • Installing the 2-Channel SFP-Based Wavelength Converter, page 11 Required Tools You will need these tools to install the 2-Channel SFP-Based Wavelength Converter: • Number 2 Phillips screwdriver for t
Installing the 2-Channel SFP-Based Wavelength Converter Mounting the 2-Slot Chassis in the Rack 68818 Figure 2 Installing the 2-Channel SFP-Based Wavelength Converter Caution When performing the following procedures, wear a grounding strap around your wrist to avoid ESD damage to the converter. Make sure that the other end of the ground strap is securely attached to a grounded point.
Installing the 2-Channel SFP-Based Wavelength Converter Installing a 2-Channel SFP-Based Wavelength Converter 130168 Figure 3 Step 3 Gently push the converter chassis into the open slot in the 2-slot chassis. Ensure that you line up the captive screws on the converter with the screw holes on the 2-slot chassis. Step 4 Continue pushing the converter chassis into the open slot until the converter chassis faceplate makes contact with the 2-slot chassis faceplate.
Installing the SFP Transceivers Installing the SFP Transceivers Caution We strongly recommend that you do not install or remove the SFP transceiver module with fiber-optic cables attached to it because of the potential damage to the cables, the cable connector, or the optical interfaces in the SFP transceiver. Disconnect all cables before removing or installing an SFP transceiver. Removing and installing an SFP transceiver can shorten its useful life.
Installing the SFP Transceivers SFP Module with a Bale-Clasp Latch 63067 Figure 7 To install an SFP transceiver, follow these steps: Step 1 Attach an ESD-preventive wrist strap to your wrist and to the ESD ground connector or a bare metal surface on your chassis. Step 2 Remove the SFP transceiver module from its protective packaging. Note Do not remove the optical bore dust plugs until you are directed to do so later in the procedure.
Cabling the 2-Channel SFP-Based Wavelength Converter Cabling the 2-Channel SFP-Based Wavelength Converter Warning Note Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments.
Regulatory Compliance Figure 9 Cabling the 2-Channel Wavelength Converter Module 1000BASE-LX/LH 1000BASE-LX/LH SFP CWDM SFP 130170 To system ground To source AC To Network 1 Regulatory Compliance This section includes all regulatory, safety, EMC (Class A or Class B), telecom, and NEBS standards. The 2-Channel SFP-Based Wavelength Converter is in compliance with the national and international standards that are listed in Table 2.
Regulatory Compliance Table 2 Specification Regulatory Standards Compliance Standard AS/NZS 60950 21CFR1040 ENG-60825-1 IEC 60825-1 EMC FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55022 Class A CISPR 22 Class A CISPR 24 AS/NZS 3548 Class A VCCI Class A EN 55024 EN 300 386 EN 50082-1 EN61000-6-1 Cisco 2-Channel SFP-Based Wavelength Converter Installation Note 78-16648-01 17
Translated Safety Warnings Translated Safety Warnings This section contains the translations to the warnings that appear in this publication. Statement 1008—Class 1 Laser Product Warning Waarschuwing Varoitus Class 1 laser product. Klasse-1 laser produkt. Luokan 1 lasertuote. Attention Produit laser de classe 1. Warnung Laserprodukt der Klasse 1. Avvertenza Prodotto laser di Classe 1. Advarsel Laserprodukt av klasse 1. Aviso Produto laser de classe 1.
Translated Safety Warnings Statement 1030—Equipment Installation Warning Waarschuwing Varoitus Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door bevoegd geschoold personeel. Tämän laitteen saa asentaa, vaihtaa tai huoltaa ainoastaan koulutettu ja laitteen tunteva henkilökunta.
Translated Safety Warnings Advarsel Aviso ¡Advertencia! Varning! Aviso Advarsel Bare opplært og kvalifisert personell skal foreta installasjoner, utskiftninger eller service på dette utstyret. Apenas pessoal treinado e qualificado deve ser autorizado a instalar, substituir ou fazer a revisão deste equipamento. Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo.
Translated Safety Warnings Statement 1040—Product Disposal Warning Waarschuwing Varoitus Ultimate disposal of this product should be handled according to all national laws and regulations. Het uiteindelijke wegruimen van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. Tämä tuote on hävitettävä kansallisten lakien ja määräysten mukaisesti.
Translated Safety Warnings Aviso Advarsel O descarte definitivo deste produto deve estar de acordo com todas as leis e regulamentações nacionais. Endelig bortskaffelse af dette produkt skal ske i henhold til gældende love og regler.
Translated Safety Warnings Statement 1051—Laser Radiation Warning Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into beams or view directly with optical instruments. Waarschuwing Losgekoppelde of losgeraakte glasvezels of aansluitingen kunnen onzichtbare laserstraling produceren. Kijk niet rechtstreeks in de straling en gebruik geen optische instrumenten rond deze glasvezels of aansluitingen.
Translated Safety Warnings Aviso Advarsel Radiação laser invisível pode ser emitida a partir de fibras ou conectores desconectados. Não fixe o olhar nos feixes e nem olhe diretamente com instrumentos ópticos. Usynlig laserstråling kan forekomme fra brugte fibre eller stik. Stir ikke ind i stråler eller direkte med optiske instrumenter.
Translated Safety Warnings Statement 1057—Hazardous Radiation Exposure Warning Waarschuwing Varoitus Use of controls, adjustments, or performing procedures other than those specified may result in hazardous radiation exposure. Het gebruik van regelaars of bijstellingen of het uitvoeren van procedures anders dan opgegeven kan leiden tot blootstelling aan gevaarlijke straling.
Translated Safety Warnings Aviso O uso de controles, ajustes ou procedimentos diferentes daqueles especificados pode resultar em exposição perigosa à radiação. Advarsel Brug af kontrolfunktioner, justeringer, eller udførelse af procedurer andre end de, der er angivet, kan resultere i udsættelse for farlig bestråling.
Obtaining Documentation and Submitting a Service Request Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.
Obtaining Documentation and Submitting a Service Request Cisco 2-Channel SFP-Based Wavelength Converter Installation Note 28 78-16648-01