MegaRAID SAS Controller Replacement Procedure OL-27138-01 MegaRAID SAS Controller Replacement Procedure For CDE220, CDE420 and CDE250 servers Version 1.9 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Table of Contents Table of Contents ........................................................................................................ 2 Overview ......................................................................................................................... 5 Front Panel.................................................................................................................. 5 Rear Panel .....................................
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Appendix D ................................................................................................................... 57 Procedure to clear the existing configuration on a 9261-8i MegaRAID controller card without risking the configuration on internal disk drives ............................................. 57 All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Document Revision History The Document Revision History table below records technical changes to this document. Document Version Date Change Summary Initial Version 1.0 March 1, 2012 Initial version Version 1.1 April 20, 2012 General clean up Version 1.2 April 27, 2012 Added diagrams for the CDE250 Version 1.3 May 5, 2012 Edited step 1.1 ( upgrade procedures) for each server Version 1.4 May 25, 2012 Updates for the FW Package 12.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Overview This document details the replacements of the build-in internal card MegaRAID SAS Controller AOC-SASLP-H8iR-CI025 in CDE220, CDE420 and CDE 250 servers with the newer one. The existing card in PCI slot 3 (from left to right when facing to the rear panel of the chassis) is to be replaced with the newer card. The controller card change is required to resolve the following: 1.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Rear Panel Slot 4 aligns with motherboard Slot 3 Figure 4: CDE220 Rear Panel View Mother Board Layout Figure 5: CDE-XX Mother Board View All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Rear Panel Figure 6: Rear View of CDE250 Mother Board Layout Figure 7: CDE-250 Mother Board View Upgrade Overview: Cisco recommends that Comcast should upgrade the CDS Devices in the following order: Streamers CGW Vaults Upgrade Times for each device: 45 minutes. All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Replacement Preparations Make sure you have received the new MegaRAID card (LSI MegaRAID 9261-8i). Ensure that the BBU is either on the card or present in the box. Make sure you have downloaded the initrd.img installer which will install the new SAS driver to support the new MegaRAID controller. This installer will need to be copied over to the server that its MegaRAID controller will be replaced with the new one.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 power supplies and disconnect all the cables on the rear panel for physically replacing the MegaRAID controller. 5. Open the chassis to replace the old MegaRAID controller with the new one. 6. Import logical drive configuration from the physical drives to the new card, if prompted to do so. 7. Upgrade the firmware for the new MegaRAID controller by using the DOS bootable USB key with the new firmware. 8.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 d. At the end of that line backspace to ‘LABEL=/’ , hit spacebar and type in 'single' Figure 9: Bash e. hit RETURN f. Type in 'b' for boot g. Wait for bootup to complete into single mode prompt where the system would perform a file system health check upon reboot. Note the ‘clean’ status for each partition. boot up messages. Checking filesystems Checking all file systems. [/sbin/fsck.ext3 (1) -- /] fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Upgrade Procedure for Streamers 1. Installing the new SAS driver Note: if the server is running with CDS-TV 2.5.3 or later version, skip this step as the new SAS driver is already included in the 2.5.3 image. 1. Install the new SAS driver before shutting down the server and replacing the MegarRAID card. 2. To install the new SAS driver: o o o SSH as root to the device that is targeted for an upgrade. Copy over the initrd.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 3. Power off the server, disconnect the power cords from the power supplies, remove the power supplies and disconnect all the cables on the rear panel. 4. Place the chassis on a workstation and remove the top cover; 5. Note: Make sure you have an ESD strap on and you are properly grounded before doing the following steps: 6. Unscrew the bracket of card at slots 3.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 MegaRAID controller. This can be done when initializing the new MegaRAID controller during the first booting up after replacing the controller if prompted. 1. Power up the server. During the first time after replacing the MegaRAID controller, if the following messages ” Memory/battery problems were detected” “The adapter has recovered, but cached data was lost” are seen as in the below figure, then press any key to continue.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 2. When these messages are shown up, type ‘F’ to import logical drive configuration from the internal physical drive to the new MegaRAID controller, and then continue. 3. After typing ‘F’, more messages will be shown. Please refer to Figure 12 below. 4. Press ‘C’ to load the configuration utility and verify the configuration. A few more messages are displayed. 5.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Note: If Foreign Configuration cannot be imported, please refer to Appendix D to clear the existing configuration on the MegaRAID SAS controller card, card have been previously used or tested and retains cache. If you see following screen (Figure 14) indicating offline Virtual drives, please refer to Appendix D: Figure 14: WebBIOS found existing offline Virtual Drives 7. Click on “Start” button to get the current controller configuration.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 16: WebBIOS Foreign Configuration Preview Figure 17: Correct Logical Drive Information 8. If the information in Figure 16 is not shown on your screen, the MegaRAID configuration may not be imported correctly. In this case, please ‘Exit’ the utility without saving the configuration, then power cycle it to import the configuration again by repeating this step. 9. Select Exit ->Yes ->reboot the server by turning on and off the power button.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 18: LSI Reboot prompt 10. If the information in Figure 17 is shown on the screen, the configuration is correctly imported. The server will boot up properly, then. 11. If the prompt to import the “Foreign configuration” was not seen, verify the configuration by loading the WebBIOS when prompted by entering “-H”. Follow the same procedure as mentioned after Figure 12 (Figure 12 through 17).
MegaRAID SAS Controller Replacement Procedure OL-27138-01 1. Check for LED status on the interface ports 2. When the Streamer starts its POST procedure, enter the system BIOS setup by pressing within the first 10 seconds and while the “enter BIOS” option is displayed on the screen. When in the BIOS confirm the following elements below, save the BIOS settings and reboot.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 20: GRUB d. At the end of that line backspace to ‘LABEL=/’ , hit spacebar and type in 'single' Figure 21: Bash e. hit RETURN f. Type in 'b' for boot g. Wait for bootup to complete into single mode prompt where the system would perform a file system health check upon reboot. Note the ‘clean’ status for each partition. boot up messages. Checking filesystems Checking all file systems. [/sbin/fsck.ext3 (1) -- /] fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 6. After the file system check is complete and clean, reboot and verify that the Streamer shows up Green in the CDSM/VVIM and remove the offload status at the following menu: Maintain/Server/Server Offload Online/Disable 7. On site engineer login using username “root”, password “rootroot” .
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 22: GRUB d. At the end of that line backspace to ‘LABEL=/’ , hit spacebar and type in 'single' Figure 23: Bash e. hit RETURN f. Type in 'b' for boot g. Wait for bootup to complete into single mode prompt where the system would perform a file system health check upon reboot. Note the ‘clean’ status for each partition. boot up messages. Checking filesystems Checking all file systems. All contents are Copyright © 2012 Cisco Systems, Inc.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 [/sbin/fsck.ext3 (1) -- /] fsck.ext3 -a /dev/hda2 /1: ]clean, 23750/1937280 files, 346328/1935832 blocks [/sbin/fsck.ext3 (1) -- /var] fsck.ext3 -a /dev/sda3 [/sbin/fsck.ext3 (2) -- /boot] fsck.ext3 -a /dev/hda1 /boot: clean, 52/64256 files, 45271/257008 blocks /var1: clean, 182/2560864 files, 122093/2560359 blocks [/sbin/fsck.ext3 (1) -- /home] fsck.ext3 -a /dev/sda2 /home1: clean, 380/7685440 files, 336081/7679070 blocks [/sbin/fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 -rw-r--r-- 1 root root 2544113 Jan 31 10:22 initrd-2.6.18-53.el5.cdstv.25x.r222.img -rw-r--r-- 1 root root 2511703 Jan 31 10:20 initrd-2.6.18-53.el5.cdstv.25x.r222.img_bkup Verify the size and MD5 checksum of initrd.img For example, for initrd-2.6.18-53.el5.cdstv.2.5.2.b222.img for 2.5.2 above, size is is 2544113 bytes. And its MD5 checksum is 459d14e40b0967fa0db5ee1ee24270cf # md5sum initrd-2.6.18-53.el5.cdstv.25x.r222.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 24: New MegaRAID controller 10. Install the new MegaRAID controller card into slot 3 – ensuring it is fully seated into the PCIe slot. 11. Re-attach slot screw to firmly attach new SAS controller into slot 3, and check that all slots screws are tightened. 12. Replace the top cover and put the chassis back. 13.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 25: Messages displayed on the screen Note: If the prompt to import the “Foreign configuration” was not seen as above, go to #10. 2. When these messages are shown up, type ‘F’ to import logical drive configuration from the internal physical drive to the new MegaRAID controller, and then continue. 3. After typing ‘F’, more messages will be shown. Please refer to Figure 26 below. 4.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 26: Messages displayed on the screen after typing ‘F’ and ‘C’ 6. After loading the WebBIOS configuration utility, the following screen will be displayed: Figure 27: Getting into MegaRAID WebBIOS Configuration Utility Note: If Foreign Configuration cannot be imported, please refer to Appendix D to clear the existing configuration on the MegaRAID SAS controller card, card have been previously used or tested and retains cache.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 28: WebBIOS found existing offline Virtual Drives 7. Click on “Start” button to get the current controller configuration. In case you see the screen below “ Foreign Configuration Found, Want to Import?” Click on “Preview” to go to the next screen “ Foreign Configuration As Imported. Click IMPORT to Import and merge this configuration”.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 30: WebBIOS Foreign Configuration Preview Figure 31: Correct Logical Drive Information 8. If the information in Figure 31 is not shown on your screen, the MegaRAID configuration may not be imported correctly. In this case, please Exit the utility without saving the configuration, then power cycle it to import the configuration again by repeating this step. 9. Select exit >yes >reboot the server by turning on and off the power button.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 32: LSI Reboot prompt 10. If the information in Figure 31 is shown on the screen, the configuration is correctly imported. The server will boot up properly, then. 11. If the prompt to import the “Foreign configuration” was not seen, verify the configuration by loading the WebBIOS when prompted by entering “-H”. Follow the same procedure as mentioned after Figure 25 (Figure 25 through 30).
MegaRAID SAS Controller Replacement Procedure OL-27138-01 the screen. When in the BIOS confirm the following elements below, save the BIOS settings and reboot. Advanced -> Console Redirection: Console Type is set to VT100, 8 bit Baud rate is set to 9600 Flow Control is set to XON/XOFF Default Values: Advanced -> Advanced Chipset Control -> SERR Signal Condition: is set to “Uncorrectable” Advanced -> Advance Chipset Control -> Max Payload Size: 128B 3.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 35: GRUB d. At the end of that line backspace to ‘LABEL=/’ , hit spacebar and type in 'single' Figure 36: Bash e. hit RETURN f. Type in 'b' for boot g. Wait for bootup to complete into single mode prompt where the system would perform a file system health check upon reboot. Note the ‘clean’ status for each partition. boot up messages. Checking filesystems Checking all file systems. [/sbin/fsck.ext3 (1) -- /] fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 [/sbin/fsck.ext3 (2) -- /boot] fsck.ext3 -a /dev/hda1 /boot: clean, 52/64256 files, 45271/257008 blocks /var1: clean, 182/2560864 files, 122093/2560359 blocks [/sbin/fsck.ext3 (1) -- /home] fsck.ext3 -a /dev/sda2 /home1: clean, 380/7685440 files, 336081/7679070 blocks [/sbin/fsck.ext3 (1) -- /arroyo] fsck.ext3 -a /dev/sda6 /arroyo1: clean, 1219/217808896 files, 8531636/217785164 blocks [/sbin/fsck.ext3 (1) -- /arroyo/db] fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 3. Perform a file system health check prior to the card replacement. This step is to be performed in single user mode. a. Bootup the server b. Druing bootup, when list of Linux versions appears on the screen, select CDS TV Linux version and hit 'e' for edit. c. Hit 'e' again on 2nd line as shown below Figure 37: GRUB d. At the end of that line backspace to ‘LABEL=/’ , hit spacebar and type in 'single' Figure 38: Bash e.
MegaRAID SAS Controller Replacement Procedure f. OL-27138-01 Type in 'b' for boot g. Wait for bootup to complete into single mode prompt where the system would perform a file system health check upon reboot. Note the ‘clean’ status for each partition. boot up messages. Checking filesystems Checking all file systems. [/sbin/fsck.ext3 (1) -- /] fsck.ext3 -a /dev/hda2 /1: ]clean, 23750/1937280 files, 346328/1935832 blocks [/sbin/fsck.ext3 (1) -- /var] fsck.ext3 -a /dev/sda3 [/sbin/fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 2. Verifying the new initrd.img 1. After executing the command above, the original initrd.img file will be renamed with the prefix of “_bkup” in /boot directory and the new initrd.img file will be placed into /boot to replace the old one. For example, on a server running with 2.5.2 release image, the following two lines in /boot are expected after executing the installer: -rw-r--r-- 1 root root 2544113 Jan 31 10:22 initrd-2.6.18-53.el5.cdstv.25x.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 39: New MegaRAID controller 10. Install the new MegaRAID controller card into slot 3 – ensuring it is fully seated into the PCIe slot; 11. Re-attach slot screw to firmly attach new SAS controller into slot 3, and check that all slots screws are tightened. 12. Replace the top cover and put the chassis back. 13.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 40: Messages displayed on the screen Note: If the prompt to import the “Foreign configuration” was not seen as above, go to #10. 2. When these messages are shown up, type ‘F’ to import logical drive configuration from the internal physical drive to the new MegaRAID controller, and then continue. 3. After typing ‘F’, more messages will be shown. Please refer to Figure 41 below. 4.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 41: Messages displayed on the screen after typing ‘F’ and ‘C’ 6. After loading the WebBIOS configuration utility, the following screen will be displayed: Figure 42: Getting into MegaRAID WebBIOS Configuration Utility Note: If Foreign Configuration cannot be imported, please refer to Appendix D to clear the existing configuration on the MegaRAID SAS controller card, card have been previously used or tested and retains cache.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 43: WebBIOS found existing offline Virtual Drives 7. Click on “Start” button to get the current controller configuration. In case you see the screen below “ Foreign Configuration Found, Want to Import?” Click on “Preview” to go to the next screen “ Foreign Configuration As Imported. Click IMPORT to Import and merge this configuration”.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 45: Foreign Configuration Preview Figure 46: Correct Logical Drive Information 8. If the information in Figure 46 is not shown on your screen, the MegaRAID configuration may not be imported correctly. In this case, please Exit the utility without saving the configuration, then power cycle it to import the configuration again by repeating this step. 9.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 47: LSI Reboot prompt 11. If the prompt to import the “Foreign configuration” was not seen, verify the configuration by loading the WebBIOS when prompted by entering “-H”. Follow the same procedure as mentioned after Figure 42 (Figure 42 through 47). Figure 48: MegaRAID controller card correct initialization and Firmware Post-Upgrade Procedure for Persistent Stores: 1. Check for LED status on the interface ports 2.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Baud rate is set to 9600 Flow Control is set to XON/XOFF Default Values: Advanced -> Advanced Chipset Control -> SERR Signal Condition: is set to “Uncorrectable” Advanced -> Advance Chipset Control -> Max Payload Size: 128B 3. After rebooting, check the firmware version of the SAS controller. This will appear after the BIOS and first LSI adapter POST screens. Figure 49: MegaRAID controller card correct initialization and Firmware 4.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure 50: GRUB d. At the end of that line backspace to ‘LABEL=/’ , hit spacebar and type in 'single' Figure 51: Bash e. hit RETURN f. Type in 'b' for boot g. Wait for bootup to complete into single mode prompt where the system would perform a file system health check upon reboot. Note the ‘clean’ status for each partition boot up messages. Checking filesystems Checking all file systems. [/sbin/fsck.ext3 (1) -- /] fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 [/sbin/fsck.ext3 (1) -- /var] fsck.ext3 -a /dev/sda3 [/sbin/fsck.ext3 (2) -- /boot] fsck.ext3 -a /dev/hda1 /boot: clean, 52/64256 files, 45271/257008 blocks /var1: clean, 182/2560864 files, 122093/2560359 blocks [/sbin/fsck.ext3 (1) -- /home] fsck.ext3 -a /dev/sda2 /home1: clean, 380/7685440 files, 336081/7679070 blocks [/sbin/fsck.ext3 (1) -- /arroyo] fsck.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 6. Import the Logical Drive Configuration (for details, see section 4 of the new MegaRAID replacement MOP) 7. Press ‘X’, to continue and press ‘Y’ following the figure 51 below: Figure 51: Prompt to enter the WebBIOS configuration Utility 8. Reboot the server to normal state All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Appendix A Procedure for Upgrading firmware revision for the new MegaRaid controller 1. If the new MegaRAID controller FW package is not 12.12.0-0090: o Download the FW package “10M09 P24” and MegaCli for DOS at: http://www.lsi.com/Search/Pages/results.aspx?k=12.12.0-0090 o Once you navigated to this page: Click on 12.12.0-0090_SAS_2108_FW_Image_APP-2.120.2431482.txt to download and save Click on the “10M09 P24” link to download the “12.12.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 7. During booting up, check the firmware package version by looking at the following message to verify the new firmware installed properly. Figure 2A: Initializing the MegaRAID controller after Firmware upgraded 8.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Appendix B Procedure to install/ replace the BBU on the Controller Card 1. Unscrew the 3 screws on the rear of the card identified in the below picture. Figure 1B: MegaRAID 9261-8i 2.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 4. Replace the Low Profile PCI bracket with the Full Height PCI bracket and reattach two screws removed in step 5-c above 5. Re-install the BBU by connecting the BBU to the controller connector and reattaching the 3 screws to the rear of the card which were removed in step 1 above All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Appendix C Network Interface diagrams and NIC numbering Overview This document will provide detailed chassis layout and interface numbering for the Ethernet controllers in the CCDN hardware servers. Due to a recent SAS controller field replacement, the previous Ethernet controller slots may have changed from earlier documentation. This document will supersede earlier Cisco CDE server documentation.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 CCDN Content Library (CDE420-4A-C) The CCDN CDE420-4A-C Content Library servers have (2) On-Board Ethernet NICs and (8) PCIE Ethernet NIC interfaces. The PCI-E Quad Ethernet controllers are installed in slots 1 and 2, running from left to right when viewing the back of the server.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 CCDN Caching Gateway (CDE420-4G-C) The CCDN CDE420-4G-C Caching Gateway servers have (2) On-Board Ethernet NICs and (12) PCI-E Ethernet NIC interfaces. The PCI-E Quad Ethernet controllers are installed in slots 1,2 and 4 running from left to right when viewing the back of the server. Note that on CGW01 interface eth13 will be the C2 interface and on CGW02 eth13 will be the C2 Interface.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 CCDN Caching Gateway (CDE420-4G-F) The CCDN CDE420-4G-F Caching Gateway servers have (2) On-Board 10/100/100 Ethernet NICs and (12) PCI-E Fiber-based SFP Ethernet NIC interfaces. The PCI-E Quad Fiber Ethernet controllers are installed in slots 1,2 and 4 running from left to right when viewing the back of the server. Note that on odd numbered CGWs, interface eth13 will be the C2 interface and on even numbered CGWs eth13 will be the C2 Interface.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 CCDN Stream Server (CDE220-2C2-C) The CCDN CDE220-2C2-C Streaming servers have (2) On-Board Ethernet NICs and (12) PCI-E Ethernet NIC interfaces. The PCI-E Quad Ethernet controllers are installed in slots 1,2 and 4 running from left to right when viewing the back of the server.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 CCDN SSD Stream Server (CDE220-2S3-F) The CCDN CDE220-2S3-F Streaming servers are flash-disk based and have Fiber interfaces instead of copper. They have (2) On-Board Ethernet NICs and (4) PCI-E Dual-Port Fiber 1000bT Ethernet NIC interfaces. The (2) port fiber NIC controllers are installed in slots 2,3 and 5 running from left to right when viewing the back of the server.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 CDE-250-2S6 and CDE250-2G3 The server has 2GbE NIC ports mounted on the baseboard that are accessible from the rear of the device. Copper is the only available option. Additional Ethernet ports are added via PCIExpress slots on the rear of the system.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Appendix D Procedure to clear the existing configuration on a 9261-8i MegaRAID controller card without risking the configuration on internal disk drives 1. Shutdown and power off the system 2. Open the system and remove the SAS cable from the MegaRAID card 3. Boot the server, use Ctrl-H command to enter WebBIOS configuration when prompted at The MegaRAID BIOS prompt Figure D1- MegaRaid prompt during bootup 4.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 Figure D3: MegaRAID WebBIOS Configuration Options Menu 6. Select “Clear Configuration” and select “Next” Figure D4: MegaRAID WebBIOS Configuration Wizard Options Answer “Yes” to the “Destructive” message Once the clear completes, “Exit” the WebBIOS utility Power off the system The MegaRAID controller cached configuration will now be cleared just like a new controller 11. Open the system and attach the SAS cable to the MegaRAID controller card 12.
MegaRAID SAS Controller Replacement Procedure OL-27138-01 14. Validate virtual and physical drive configuration ( see picture below) Figure D5: MegaRAID WebBIOS shows correctly added Virtual and Physical Drives 15. If correct, exit WebBIOS utility, reset server and let the server boot to Linux/CDS. All contents are Copyright © 2012 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.