Release Notes
39
Release Notes for the Catalyst 4500E Series Switch, Cisco IOS XE Release 3.3.xSG
OL-26675-02
Caveats
Caveats
Caveats describe unexpected behavior in Cisco IOS releases. Caveats listed as open in a prior release are
carried forward to the next release as either open or resolved.
Note For the latest information on PSIRTS, refer to the Security Advisories on CCO at the following URL:
http://www.cisco.com/en/US/products/products_security_advisories_listing.html
Open Caveats for Cisco IOS XE Release 3.3.2SG
This section lists the open caveats for Cisco IOS XE Release 3.3.2SG:
• On a Catalyst 4500 series switch, running Cisco IOS-XE Release 03.03.2SG, QoS service policies
are applied on VLANs where the user has not configured this.
For example, if a Catalyst 4500 series switch has two groups of VLANs defined in VLAN
configuration mode:
–
A- 1 group only has QoS defined
–
B- 1 group only has Netflow defined
When you enter the VLAN configuration mode for a VLAN that belongs to group A and configure
the same NetFlow policy present in group B, ALL group B VLANs inherit the QoS configuration,
even if you do not apply it.
The problem is seen only on a Catalyst 4500 series switch, running Cisco IOS-XE Release
03.03.2SG
Workaround: None. CSCus20676
• When an SNMP query includes the cpmCPUProcessHistoryTable, the query time is very slow, and
CPU utilization of the os_info_p process (OS Info provider) increases substantially. The time
required for a full walk of an almost fully populated table is 68 minutes.
Workaround: None. CSCth42248
• The show ipv6 access-list command displays incorrect match counts when multicast traffic is
matched to an IPv6 access list that is attached to an SVI.
Workaround: None. CSCth65129
• When either the RADIUS-server test feature is enabled or RADIUS-server dead-criteria is
configured, and either RADIUS-server deadtime is set to 0 or not configured, the RADIUS-server
status is not properly relayed to AAA.
Workaround: Configure both dead-criteria and deadtime.
radius-server dead-criteria
radius-server deadtime
CSCtl06706
• When you configure open authentication and perform SSO, the spanning tree state and MAC address
are not synchronized to the new standby supervisor engine. This behavior interrupts traffic only after
the second switchover because the new standby supervisor engine possesses the wrong state after
the initial switchover and the second switchover starts the port in the blocking state.
Workaround: Enter shut and no shut on the port to synchronize the STP state. CSCtf52437