White Paper
© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 24 of 25
Figure 12 shows a stack without redundant connections. When the FlexStack link indicated by B breaks, the
FlexStack will break into two logical switches. The top two members will form one logical stack with two members,
and the other logical stack will contain a single member.
Figure 12. Broken Stack
Since the stack in the connection in Figure 12 has broken into two, only two members will have their stack port
status shown. The third member has been removed from the stack.
Stack port connections for the broken stack shown in Figure 12:
C2960-48#show switch
Switch/Stack Mac Address : 0022.bdc4.1d80
H/W Current
Switch# Role Mac Address Priority Version State
----------------------------------------------------------
*1 Master 0022.bdc4.1d80 1 1 Ready
2 Member 0022.bdc4.2300 1 1 Ready
3 Member 0000.0000.0000 0 1 Removed
C2960-NonRedundant# show switch stack-ports
Switch # Port 1 Port 2
-------- ------ ------
1 Ok Down
2 Ok Down
C2960-NonRedundant# show switch neighbors
Switch # Port 1 Port 2
-------- ------ ------
1 2 None
2 1 None
Member 1 connects to
member 2, each on port 1.