Figure 9. Adding a New Member to an Existing Stack
If all went well, traffic on the exiting members was minimally interrupted. There were at least two interruptions. The
first occurred when the FlexStack cable was removed in step 3. The other interruption occurred when the new
switch joined the stack after being powered on (step 7). In between the two interruptions, traffic will continue to be
switched over the existing members and the operational FlexStack links.
Removing Members from an Existing Stack
FlexStack remembers all members that have been members. When a member is physically removed or just
powered down, FlexStack still considers that switch a member, just not currently active. The reason that the stack
remembers members that have been removed is because most of the time the member comes back. For example,
when a member is powered off, then powered back on, the member will rejoin the existing stack, and all the
member-specific configuration will be reapplied when it completes the boot process. This is the most common
occurrence.
If the removal is permanent, then it is recommended that the stack configuration be “cleaned up.” The member will
be deleted from the stack configuration. Here is an example of a command to remove stack member 4 from the
configuration after it has been physically removed from the stack:
C2960-48(config)#no switch 4 provision