Technical Manual

ANTK
default − ANI identifier number
SIGO STD default − Signaling arrangement − std, could be
ESN3, ...
ICIS YES
default − Incoming Identifier Send − yes
TIMR ICF
512
default − Trunk timer: Incoming Flash − 512ms
OGF 512
default − Trunk timer: Outgoing Flash − 512ms
EOD
13952
default − Trunk timer: End of Dial − 13952ms
NRD
10112 default − Trunk timer: No Ringing Detector −
10112ms
DDL 70
default − Trunk timer: Dial Delay − 70ms
ODT 4096 default − Trunk timer: End of dial for DIGITONE
trunks − 4096ms
RGV 640
default − Trunk timer: Ring Validation − 640ms
GRD 896
default − Trunk timer: Guard − 896ms
SFB 3
default − Trunk timer: Seize Fail Busy − 3s
NBS 2048 default − Trunk timer: Enblock Short dialing −
2048ms
NBL 4096 default − Trunk timer: Enblock Long dialing −
4096ms
IENB 5 default − Trunk timer: Idle Extension Notification
Block − 5s
TFD 0 default − Trunk timer: Timed Forced Disconnect −
0s
DRNG NO default − North American Distinctive Ringing? −
no for tie trunks to have normal ringing
CDR NO
default − Call Detail Recording for this route? − no
MUS NO
default − Music on hold? − no
RACD NO default − Route traffic information in ACD reports?
− no
OHQ NO
default − Off−Hook Queuing? − no
PAGE 002
page 2 of this report
OHQT 00
default − Off−Hook Queue Threshold − 0s
CBQ NO
default − Call Back Queuing? − no
AUTH NO default − Authorization code to be prompted for
incoming NARS/BARS calls? − no
TDET NO
default − Tone Detector required? − no