Manual
DescriptionRequired Information
IPv4/IPv6 addresses assigned to the S1-MME interface as SCTP bond
address.This address will be used for binding the SCTP (local bind
address(es)) to communicate with the MME using eGTP. The HeNB-GW
passes this IP address during setting up the association with the MME.
Multiple addresses and subnets are needed if multiple interfaces will be
configured.
S1-MME interface IP address
Mobile Country Code (MCC): The MCC can be configured to any
integer value from 0 to 999.
Public Land Mobile Network
(PLMN) Identifiers
Mobile Network Code (MNC): The MNC can be configured to any
integer value from 0 to 999.
The physical port to which is used to communicate with the HeNBs over
S1-MME interface. It is usually an integer value ranging from 1 to 65535.
S1-MME SCTP Port
MME Group ID to be configured for the HeNB-GW Access Service.
This is a required parameter since the HeNB-GW acts as an MME to the
HeNB(s) and this ID is filled in the S1-SETUP response sent to the
HeNB(s). It is an integer ranging from 32768..65535.
MME ID Group ID
MME Code is also part of the MME ID configuration. MME Group ID
and MME Code both are required for MME Identifier configuration for
the HeNB-GW Access service. It is an integer which ranges from 0..255.
MME Code
Enables the S1-U relay functionality for the HeNB-GW Access Service.
Once S1-U Relay is enabled, the association to Ingress and Egress GTP-U
services is considered as critical configuration for the HeNB-GW Access
service.
S1-U Relay
A pre-configured HeNB-GW Network Service is required to be associated
to the HeNB-GW Access Service. User can enter a desired HeNB-GW
Network service name even if it is not pre-configured, but it will be
required to be configured in later course for this HeNB-GW Access
service to come up.
Associate HeNB-GW Network
Service
Optional Security Gateway Configuration
This is the IP Address where the SeGW service is bound and shall be
provided to HeNB during SeGW-Discovery. This security gateway is
associated with the HeNB-GW Access Service.
Only one SeGW IP address can be configured.
Security Gateway IP address
An identification string from 1 to 63 characters (alpha and/or numeric)
by which the Diameter endpoint configuration is recognized by the system.
This Diameter Endpoint is required by the SeGW to communicate with
the AAA server.
Diameter Endpoint
Diameter Endpoint Configuration
HeNB-GW Administration Guide, StarOS Release 19
43
HeNB-GW Service Configuration Procedures
Required Destination Context Configuration Information