Page 298 Introduction
Introduction
This section contains background information on a variety of topics that may be useful for sys-
tem and voice mail administrators.
Environmental Requirements
Table 42 shows the ranges of environmental conditions for operation and storage of Inter-Tel
5000 platform equipment and endpoints.
System Capabilities
The Inter-Tel 5000 supports the telecommunication equipment required to provide seamless
integration into the Public Switched Telephone Network (PSTN) and the Internet.
Trunks and Spans
The Inter-Tel 5000 platform supports the trunks and multi-channel spans described in the fol-
lowing sections.
Central Office (CO) [Local Exchange] Trunks
Including the two loop start circuits built into the Inter-Tel 5000 Base Server, up to 14 loop
start trunks can be supported by the Inter-Tel 5000 platform. Up to three Loop Start Modules
(LSM) can be installed, and LSMs are available with either two or four ports.
T1/E1/PRI Spans
With three expansion bays, the Inter-Tel 5000 Base Server supports up to six T1, T1/PRI, or
E1/PRI spans. Single-port T1/E1/PRI modules (T1M) support one span each, and Dual T1/E1/
PRI modules (T1M-2) support two spans each. A T1 span supports up to 24 trunks; a T1/PRI
span supports up to 23 trunks; and, an E1/PRI span supports up to 30 trunks. Trunk options in
DB Programming include Loop Start, Off-Premises Extension (OPX), Direct Inward Dial
(DID) [Direct Dialing Inward (DDI), in Europe], T1, T1/PRI, E1/PRI, and T1/E&M.
NOTICE
Possible Malfunction Due to Overheating. Never exceed the maximum operating tem-
perature listed in Table 42. When installing the chassis and endpoints, allow a sufficient
margin for error in case of air conditioning failure, routine maintenance, plant shutdown,
etc. As a general guideline, if the conditions are suitable for office personnel, they are also
suitable for all equipment and endpoint operation. A properly controlled environment will
help to extend the operating life of the equipment.
Table 42. Equipment Environmental Requirements
Requirements In Operation In Storage
Temperature
Equipment Chassis
Station Instruments
Relative Humidity
(Non-Condensing)
Altitude
32 to 104 °F (0 to 40 °C)
32 to 113 °F (0 to 45 °C)
5–95%
Up to 10,000 ft (3048 m)
+40 to 185 °F (–40 to 85 °C)
–40 to 185 °F (–40 to 85 °C)
5–95%
Up to 40,000 ft (12,192 m)