Features Descriptions
Physical specifications
●
Weight: 0.75 lb (0.34 kg)
●
Height: 0.8 in. (2.03 cm) (single height)
●
Width: 6.75 in. (17.15 cm)
●
Depth: 7.28 in. (18.49 cm)
Power
●
4-port FE SPA: 12.7W
●
8-port FE SPA: 16.2 W
Environmental specifications
●
Storage temperature: –38 to 150°F (–40 to 70°C)
●
Operating temperature, nominal: 32 to 104°F (0 to 4 0°C)
●
Operating temperature, short term: 32 to 131°F (0 to 55°C)
●
Storage relative humidity: 5 to 95% relative humidity
●
Operating humidity, nominal: 5 to 85% relative humidity
●
Operating humidity, short term: 5 to 90% relative humidity
●
Operating altitude: -60 to 4000 meters
Compliance and agency
approvals
Safety
●
UL 60950-1
●
CSA C22 No. 60950-1
●
EN 60950-1
●
IEC 60950-1
●
AS/NZS 60950
●
EN 60825-1
●
EN 60825-2
●
21 CRF 1040
EMC
●
FCC Part 15-Class A
●
ICES 003-Class A
●
CISPR 22 Class A
●
EN 55022 Class A
●
EN 300386 Class A
●
AS/NRZ Class A
●
VCCI-Class A
●
EN 50082-1/EN 6100-6-1
●
EN 55024
●
BSMI Class A
●
IEC/EN61000-3-2 Power Line Harmonics
●
IEC/EN61000-3-3 Voltage Fluctuations and Flicker
●
IEC/EN61000-4-2 Electrostatic Discharge Immunity (8-kV contact, 15-kV air)
●
IEC/EN61000-4-3 Radiated Immunity (10 V/m)
●
IEC/EN61000-4-4 Electrical Fast Transient Immunity (2-kV power, 1-kV signal)
●
IEC/EN61000-4-5 Surge AC Port (4-kV CM, 2-kV DM)
●
IEC/EN61000-4-5 Surge Signal Port (1-kV indoor, 2-kV outdoor)
●
IEC/EN61000-4-5 Surge DC Port (1 kV)
●
IEC/EN61000-4-6 Immunity to Conducted Disturbances (10 Vrms)
●
IEC/EN61000-4-8 Power Frequency Magnetic Field Immunity (30 A/m)
●
IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations
Telecom
●
IEEE 802.3
Industry Standards
The Cisco Fast Ethernet SPAs are designed to meet the following requirements (some
qualifications are currently in progress):
●
SR-3580-Network Equipment Building Standards (NEBS): Criteria levels (Level 3
compliant)
●
GR-63-CORE-NEBS: Physical protection
●
GR-1089-CORE-NEBS EMC and safety
Ordering Information
To place an order, visit the Cisco Ordering Home Page or refer to Table 2.