Specifications
5-31
Catalyst 4224 Access Gateway Switch Software Configuration Guide
OL-2031-02
Chapter 5 Configuring the Voice Interfaces
T1/E1 Configuration (H.323)
Gateway 2 Configuration
dial-peer voice 1 pots
port 1/0/0
destination-pattern 2000
T1/E1 Configuration (H.323)
To configure an ISDN PRI interface or T1/E1 multiflex trunk interface on your
Catalyst 4224, use configuration mode.
This section contains the following topics:
• Configuring T1 Interfaces, page 5-31
• T1/PRI Configuration Example, page 5-33
• Configuring E1 Interfaces, page 5-33
• E1/PRI Configuration Example, page 5-34
Configuring T1 Interfaces
Use the following procedure to configure a new T1 interface or to change the
configuration of an existing interface. After completing these steps, configure the
route pattern and dial plan and save your configuration, as described in “H.323
Gateway Configuration” section on page 5-16.
Step 1 Identify the port number and enter line-specific information provided by your
local carrier.
a. Select the T1/PRI interface to configure.
c4224(config)# controller t1 1/0
This example configures a T1 interface in slot 1 and unit 0.