Datasheet
2-6
Cisco 7600 Series Router Installation Guide
OL-4503-24
Chapter 2 Preparing for Installation
Site Requirements
Table 2-4 lists the power and the heat numbers for the Policy Feature Cards (PFCs).
WS-SUP32-10GE-3B
Supervisor Engine 32 with PFC3B and
MSFC2A daughter cards
4.19 175.98 219.98 751.21 236.53 807.76
WS-SUP32-GE-3B
Supervisor Engine 32 with PFC3B and
MSFC2A daughter cards
3.69 154.98 193.73 661.57 208.31 711.37
WS-SUP720
Supervisor Engine 720 with PFC3A
daughter card and integrated MSFC3
and switch fabric
7.50 315.0 393.75 1344.66 423.39 1445.87
WS-SUP720-3B
Supervisor Engine 720 with PFC3B
daughter card and integrated MSFC3
and switch fabric
6.72 282.24 350.80 1204.81 379.35 1295.5
WS-SUP720-3BXL
Supervisor Engine 720 with PFC3BXL
daughter card and integrated MSFC3
and switch fabric
7.82 328.44 410.55 1402.03 441.45 1507.56
RSP720-3C-GE 6.90 290 362.50 1237.93 389.78 1331.11
RSP720-3CXL-GE 8.10 340.20 425.25 1452.23 457.26 1561.54
RSP720-3C-10GE 8.80 370 462.50 1579.43 497.31 1698.31
RSP720-3CXL-10GE 10 420 525 1792.87 564.51 1927.82
Table 2-3 Power Requirements and Heat Dissipation—Supervisor Engines (continued)
Model Number/
Module Type
Module
Current (A)
Module
Power
(Watts)
AC DC
AC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
Table 2-4 Power Requirements and Heat Dissipation—Policy Feature Cards (PFCs)
Model Number/
Module Type
Module
Current (A)
Module
Power
(Watts)
AC DC
AC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
WS-F6K-PFC3A
Policy Feature Card 3A
2.25 94.50 118.13 403.40 127.02 433.76
WS-F6K-PFC3B
Policy Feature Card 3B
1.47 61.74 77.18 263.55 82.98 283.39
WS-F6K-PFC3BXL
Policy Feature Card 3BXL
2.57 107.94 134.93 460.77 145.08 495.45