Step 7 Check the CRC field. The presence of many CRC errors, but not many collisions, indicates excessive
noise. If the number of errors is too high, check the cables for damage. If you are using UTP cable, make
sure you are using category 5 cables and not another type, such as category 3.
Note Errors and the input and output difference should not exceed 0.5 to 2.0 percent of traffic on
the interface.
Step 8 Check the collisions fields. These numbers indicate packet collisions, and these numbers should be very
low. The total number of collisions with respect to the total number of output packets should be 0.1
percent or less.
Step 9 Check the late collisions fields. Late collisions should never occur in a properly designed Ethernet
network. They usually occur when Ethernet cables are too long or when there are too many repeaters in
the network.
Step 10 Check carrier fields. These numbers indicate a lost carrier detect signal and can be caused by a
malfunctioning interface that is not supplying the transmit clock signal, or by a cable problem. If the
system notices that the carrier detect line of an interface is up, but the line protocol is down, it
periodically resets the interface in an effort to restart it. Interface resets can also occur when an interface
is looped back or shut down.
Step 11 Check the buffers fields. These numbers indicate the number of received packets discarded because there
was no buffer space. Broadcast storms on Ethernet networks and bursts of noise on serial lines are often
responsible for no input buffer events.
If you determine that the physical interface is configured incorrectly, refer to the “Configuring
Interfaces” chapter in the Layer 3 Switching Software Feature and Configuration Guide.
Follow these steps to troubleshoot the status of a Gigabit Ethernet interface module:
Step 1 Use the show controllers GigabitEthernet card/subcard/port command to check the configuration.