Troubleshooting SVC Connections on a PNNI Routing Network
This section contains the following procedures:
Checking the SVC Status at the End UNI Interface
Checking UNI Interfaces
Debugging SVC Signalling
Alternate SVC Diagnostics
Debugging PNNI SVC Routing
Checking ATM Routes
Checking PNNI Topology
Checking SVC Downstream
Checking the SVC Status at the End UNI Interface
Use the following commands to check SVC interface status:
Follow these steps to confirm whether there is a new SVC connection from the originating side of the
UNI interface to the intended remote or destination ATM network service access point (NSAP) address:
Step 1 Use the show atm vc signalling interface atm card/subcard/port detail command on the originating
side.
RemDvLs1# show atm vc signalling interface atm 3/1/1 detail
interface = ATM3/1/1, call remotely initiated, call reference = 19
vcnum = 0, vpi = 0, vci = 18, state = Active(EngFl1Ls1), point-to-point call
<Information Deleted>
timer currently inactive, timer value = 00:00:00
Remote Atm Nsap address: 47.0091810000000060705BD900.123412344321.11
local , Req Connect Ack -> Active(EngFl1Ls1),
<Information Deleted>
RemDvLs1#
Command Purpose
show atm vc signalling interface atm
card/subcard/port detail
Confirms the SVC connection to the
intended destination ATM NSAP address.
show atm vc interface atm card/subcard/port vpi
vci
Confirms the destination UNI connection
is up, and confirms the correct traffic