Troubleshooting guide
5-57
ATM and Layer 3 Switch Router Troubleshooting Guide
OL-1969-02
Chapter 5 Troubleshooting Switch Router ATM Interface Connections
Troubleshooting Channelized DS3 and E1 Frame Relay Interfaces
Follow these steps to display the memory management and error counters of a channelized DS3 or E1
Frame Relay interface:
Step 1 Use the show controllers atm card/subcard/port command to check memory management and error
counters.
Switch# show controller e1 1/0/1
E1 1/0/1 is up.
PAM state is Up
FPGA Version: fi-c8510-4e1fr.A.3.2
Firmware Version: fi-c8510-4e1fr.A.2.3
No alarms detected.
Framing is crc4, Line Code is HDB3, Clock Source is line.
Data in current interval (284 seconds elapsed):
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Data in Interval 1:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
.
[Information Deleted]
.
Data in Interval 95:
0 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs
0 Unavail Secs
Total Data (last 95 15 minute intervals):
8 Line Code Violations,0 Path Code Violations,
0 Slip Secs, 0 Fr Loss Secs, 4 Line Err Secs, 0 Degraded Mins,
0 Errored Secs, 0 Bursty Err Secs, 1020 Severely Err Secs
138 Unavail Secs, 0 Stuffed Secs
Switch#
Step 2 Check the fields listed in Table 5-14. It lists the best troubleshooting fields in the show controllers
command display, what those fields indicate.
Table 5-14 Channelized DS3 and E1 Frame Relay Port Adapter show controller Display
Field
Indication
(Severity) Error and Cause Recommendation
PAM state Up None None
down
• Disconnected or faulty cabling
• Hardware failure
Check for the following:
• Check cables.
• Replace faulty hardware.
administratively
down
The interface has been administratively
taken down.
Use the no shutdown interface
configuration command to reenable the
interface.