Datasheet
Data Sheet
© 2010 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 10 of 14
Cisco 2800 Series Cisco 2801 Cisco 2811 Cisco 2821 Cisco 2851
Power Requirements
AC Input Voltage 100 to 240 VAC,
autoranging
AC Input Frequency 47-63 Hz
AC Input Current 2A (110V) 1A (230V) 3A (110V) 2A (230V)
AC Input Surge Current 50A maximum, one cycle
(-48V power included)
AC-IP Maximum In-Line
Power Distribution
120W 160W 240W 360W
AC-IP Input Current 4A (110V) 2A (230V) 8A (110V) 4A (230V)
AC-IP Input Surge Current 50A maximum, one cycle
(-48V power included)
DC Input Voltage No DC Power Option
available
24 to 60 VDC, autoranging
positive or negative
DC Input Current
●
No DC Power Option
available
●
8A (24V)
●
3A (60V)
●
Startup current 50A<10
ms
●
12A (24V)
●
5A (60V)
●
Startup current
50A<10 ms
Typical Power Dissipation
(No Modules)
42W (143 BTU/hr) 32W (109 BTU/hr) 54W (184 BTU/hr) 58W (197 BTU/hr)
Power Dissipation-AC
without IP Phone Support
150W (511 BTU/hr) 170W (580 BTU/hr) 280W (955 BTU/hr) 280W (955 BTU/hr)
Power Dissipation-AC with
IP Phone Support-System
Only
150W (511 BTU/hr) 210W (717 BTU/hr) 310W (1058 BTU/hr) 370W (1262 BTU/hr)
Power Dissipation-AC
with IP Phone Support-
IP Phones
180W (612 BTU/hr) 160W (546 BTU/hr) 240W (819 BTU/hr) 360W (1128 BTU/hr)
Power Dissipation-DC Not applicable 180W (614 BTU/hr) 300W (1024 BTU/hr) 300W (1024 BTU/hr)
RPS No External only, connector for
RPS provided by default
Recommended RPS Unit No RPS option Cisco RPS-2300
Redundant Power System
Environmental Specifications
Operating Temperature 32° to 104°F (0° to 40°C)
Non-Operating
Temperature
-4° to 149°F (-20° to 65°C) -40° to 158°F (-40° to
70°C)
Maximum Operating
Temperature at Altitude
●
40°C @ sea level
●
31°C @ 6,000 ft
(1800 m)
●
25°C @ 10,000 ft
(3000 m)
Note: Derate 1.5°C per
1000 ft
●
40°C @ sea level
●
40°C @ 6,000 ft
(1800 m)
●
30°C @ 13,000 ft
(4000 m)
●
27.2°C @ 15,000 ft
(4600 m)
Note: Derate 1.4°C per
1,000 ft above 6,000 ft
Operating Humidity 10 to 85% RH non-
condensing
5 to 85%RH, non-
condensing
Dimensions (H x W x D)
●
1.72 x 17.5 x 16.5 in.
●
(43.7 x 445 x 419 mm)
●
1.75 x 17.25 x 16.4 in.
●
(44.5 x 438.2 x 416.6
mm)
●
3.5 x 17.25 x 16.4 in.
●
(88.9 x 438.2 x 416.6
mm)
Rack Height 1 rack unit (1RU) 2RU
Weight (Fully Configured) 13.7 lb (6.2 kg) 14 lb (6.4 kg) 25 lb (11.4 kg)