Specifications
33-6
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 33 AT3-6ME (T3 to T2) Interface Adapter
Installation
Installation
Install the AT3-6ME in a rack adjacent to the BPX enclosure (allowing room for any AC Power Supply
Assembly that you might need to mount) wherever there is space for the AT3-6ME adapter.
System Connections
Two short BNC-BNC cables are required to connect the AT3-6ME to the BPX node.
Step 1 For use with BPX switch, connect one cable between one of the three TX connectors on a selected BPX
LM-3T3 card and the T3-RX connector on the AT3-6ME back panel.
Step 2 Connect the other cable between the associated RX connector on the BPX LM-3T3 or ATMT card and
the T3-TX connector on the AT3-6ME back panel.
Step 3 Connect the cable coming from the 6 Mbps facility to the T2-RX connector on the AT3-6ME.
Step 4 Connect the cable going to the 6 Mbps facility to the T2-TX connector on the AT3-6ME.
Step 5 Connect the AC power cord to the IEC connector on the rear of the AT3-6ME.
AT3-6ME Configuration
You configure the adapter by seting a group of DIP switches located on the front panel. There are two
sets of switches:
• a 12-position switch
• a two position switch.
This switch enables the configuration change via the terminal and enable/disable the loop push
button located in the front panel (to secure against accidental operation).
Review both Table 33-3 and Table 33-4. Set the appropriate DIP switches with the power off.
Table 33-3 DIP Switch SW-1 Selection Guide
Switch Position Function
1 Down Enable configuration via the TTY.
1 Up Disable configuration via the TTY (default).
2 Down Enable front panel loop push button.
2 Up Disable front panel loop push button (default).