Specifications
29-5
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 29 Troubleshooting
Troubleshooting the BPX Switch
System Troubleshooting Tools
You can perform a number of manually-initiated tests from the Cisco WAN Manager NMS console to
assist in system troubleshooting. These tests may be included in a job so they can be scheduled to run
remotely at a specified time if desired.
User-initiated Tests
Several user-initiated tests can be used to diagnose system problems. These tests are self-contained in
that they do not require the use of external test equipment. They also do not require you to place a
loopback at the far end to test both directions of transmission. These tests are listed in Table 29-3.
Several display commands can be used to obtain information that may be helpful in troubleshooting
system problems. These are also listed in Table 29-3.
Downloading
Software
There are downloader commands that appear when the
system is down- loading software to the BCC.
Minor BCC Redundancy alarm indicates node is configured for
redundancy but no standby BCC is equipped.
1. Cards with an F status (no terminal failure) are activated only when necessary. Cards with a failed status are never
activated.
Table 29-2 Card Status for the BPX Switch (continued)
Card Type Status
1
Description
Table 29-3 System Troubleshooting Commands Available
Command Description
Test Connection (tstcon)—frame relay Performs a bi-directional test of the specified frame relay connection or range of
connections by inserting a test pattern and comparing the returned pattern with the
pattern transmitted. A pass or fail indication appears next to the tested connection
in the Display Connections screen.
Test Connection (tstcon)—data Same as above except for synchronous data connections.
Test Connection (tstcon)—voice Same as above except for voice connections.
Test Delay (tstdelay)—frame relay Measures the round-trip delay over the selected frame relay connection.
Test Port (tstport)—frame relay Tests the operation of the selected frame relay port on the node.
Test Port (tstport)—data Same as above except for synchronous data ports.
Display Connection States (dspconst) Displays in real-time the status of all voice connections terminating at a specified
node.
Display Breakout Box
(dspbob)—frame relay
Displays in real-time the status of data and control leads on selected frame relay
connection.
Display Breakout Box (dspbob)—data Same as above for synchronous data connections.
Display Breakout Box
(dspbob)—trunk
Same as above for network subrate trunks.
Display Buses (dspbuses) Displays the status of system buses.
Display Slot Errors (dspsloterrs) Displays any data errors associated with the slots in a BPX node.