Specifications

24-6
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter24 Configuring BXM Virtual Circuits
Command Line Interface Examples
pubsbpx1 TN silves BPX 8620 9.3 March 2 2000 13:45 PDT
TRK Type Current Line Alarm Status Other End
1.1 T3 Clear - OK -
2.1 OC-3 Clear - OK VSI(VSI)
2.4 OC-3 Clear - OK -
Last Command: dsptrks
Next Command:
An example of the upln command for UNI port access on a BXM card:
pubsbpx1 TN StrataCom BPX 8620 9.3 March 2 2000 13:54 PDT
Line Type Current Line Alarm Status
2.2 OC-3 Clear - OK
2.3 OC-3 Clear - OK
Last Command: upln 2.2
256 PVCs allocated. Use 'cnfrsrc' to configure PVCs
Next Command:
Note The initial command to up a trunk (uptrk)ortoupaline(upln)ontheBXMcard
configures all the ports of the card to be either trunks or lines (UNI port access). After
using the upln command at each port, use the upport command to activate a port for UNI
access.
An example of the cnfln command: