Specifications

21-25
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 21 Configuring ATM Connections
ATM Connection Configuration
Table 21-6 Connection Parameters with Default Settings and Ranges
PARAMETER WITH [DEFAULT SETTING] BXM T3/E3, OC3 & OC12 RANGE
PCR(0+1)[50/50] 50- T3/E3 cells/sec
50 - OC3
50 - OC12
%Util [100/100]
for UBR [1/1]
0 - 100%
MCR[50/50] cells/sec
6-T3/E3OC3/0C12
FBTC (AAL5 Frame Base Traffic
Control):
for rt/nrt-VBR [disable]
for ABR/UBR [enable]
for Path connection [disable]
enable/disable
Note With the BXM, FBTC means packet discard
on queueing only.
CDVT(0+1):
for CBR [10000/10000],
others [250000/250000]
0 - 5,000,000 usec
VSVD[disable] enable/disable
FCES (Flow Control External Segment)
[disable]
enable/disable
Default Extended Parameters[enable] enable/disable
CLP Setting[enable] enable/disable
SCR [50/50] cells/sec
50 - T3/E3OC3/OC12
MBS [1000/1000] 1 - 5,000,000cells
Policing[3]
For CBR: [4]
1-VBR.1
2-VBR.2
3-VBR.3
4 - PCR policing only
5-off
ICR:
max[MCR, PCR/10]
MCR-PCRcells/sec
ADTF[1000] 62 - 8000 msec
Trm[100] ABRSTD: 1 - 100 msec
ABRFST: 3 - 255 msec
VC QDepth [16000/16000]
For ATFR/ATFST [1366/1366]
0 - 61440 cells
CLP Hi [80/80] 1 - 100%