Specifications
19-2
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 19 Configuring Circuit Lines
Setting Up a Circuit Line
Setting Up a Circuit Line
Frame relay, data, and voice connections require an active line. Before you can execute this procedure,
you must first up the card by using upcd.
To establish (or “up”) an active line:
E3 Europe
and
others
Physical Layer Convergence Protocol per
AT&T publication; ITU I-361 with HEC
for E3
HDB3 ITU-T G.804, G.832
T3 USA
Canada
Physical Layer Convergence Protocol per
AT&T publication TA-TSY-00772 and
000773 for T3
B3ZS+ M13 mode
Table 19-2 Line Card Combinations
Service Node Type Front Card Back Card
ATM IGX UXM BC-UAI
BC-UAI
BC-UAI-1T1
BC-UAI-1E1
BC-UAI-1OC3
ATM IGX ALM/A BC-UAI-1T3
BC-UAI-1E3
Frame Relay IGX UFM-4C, UFM-8C UFI-8T1-DB15,
UFI-8E1-DB15,
UFI-8E1-BNC
Frame Relay IGX FRP-6, FRP-31/FRM-6,
FRM-31
FRI-T1, FRI-E1
Frame Relay IGX UFM-C UFI-8T1-DB15
UFI-8E1-DB15 or
UFI-8E1-BNC
High Speed Data IGX SDP/HDM SDI/RS-232
SDI/RS-422
High Speed Data IGX SDP/HDM SDI/RS-232
SDI/RS-422
Voice IGX UVM BC-UVI-2T1EC
BC-UVI-2E1EC
BC-UVI-2J1EC
Voice IGX CDP/CVM BC-T1
BC-E1
BC-J1
Table 19-1 Input Line Formats (continued)
Type Country Electrical Signal Format Ones Density Enforcement Multiplexing