Specifications

5-30
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 5 BXM Card Sets: T3/E3, 155, and 622
Technical Specifications
Trunk Mode
Compliant to Bellcore GR-253-CORE
Alarms:
Loss Of Signal (LOS)
Loss Of Pointer (LOP)
Loss Of Frame (LOF)
Loss Of Cell delineation (LOC)
Alarm Indication Signal (AIS)
Remote Defect Indication (RDI)
Alarm Integration Up/down Count
Performance Monitoring:
Performance monitoring provided for Line, Section and Path
Bit Interleaved Parity (BIP) error detection
Far End Block Error (FEBE) count
Unavailable Seconds (UAS)
Errored Seconds (ES)
Severely Errored Seconds (SES)
Header Error Checksum (HCS) monitoring
Statistics:
Process Monitoring for ATM Header Cell Processing
Cells discarded due to Header Errors (LCN mismatch)
Miscellaneous ATM Layer Statistics
Number of cell arrivals from port
Number of cell arrivals with CLP = 1
Number of cells transmitted to port
Number of cells transmitted with CLP = 1
Technical Specifications
Physical Layer
Trunk or port (access) interface mode.
Compliant to SONET standards.
*Bellcore GR-253-CORE, TR-TSY-000020
*ANSI T1.105, T1E1.2/93-020RA
Compliant to SDH standards.