Specifications
5-30
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 5 BXM Card Sets: T3/E3, 155, and 622
Technical Specifications
Trunk Mode
Compliant to Bellcore GR-253-CORE
Alarms:
• Loss Of Signal (LOS)
• Loss Of Pointer (LOP)
• Loss Of Frame (LOF)
• Loss Of Cell delineation (LOC)
• Alarm Indication Signal (AIS)
• Remote Defect Indication (RDI)
• Alarm Integration Up/down Count
Performance Monitoring:
• Performance monitoring provided for Line, Section and Path
• Bit Interleaved Parity (BIP) error detection
• Far End Block Error (FEBE) count
• Unavailable Seconds (UAS)
• Errored Seconds (ES)
• Severely Errored Seconds (SES)
• Header Error Checksum (HCS) monitoring
Statistics:
Process Monitoring for ATM Header Cell Processing
• Cells discarded due to Header Errors (LCN mismatch)
Miscellaneous ATM Layer Statistics
• Number of cell arrivals from port
• Number of cell arrivals with CLP = 1
• Number of cells transmitted to port
• Number of cells transmitted with CLP = 1
Technical Specifications
Physical Layer
• Trunk or port (access) interface mode.
• Compliant to SONET standards.
–
*Bellcore GR-253-CORE, TR-TSY-000020
–
*ANSI T1.105, T1E1.2/93-020RA
• Compliant to SDH standards.