Datasheet

Data Sheet
All contents are Copyright © 1992–2006, 2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 7 of 10
Power Supply
Storage temperature –4 to 149°F (–20 to 65°C)
Relative humidity operating,
non-condensing
10 to 85% non-condensing
Relative humidity non-operating,
non-condensing
0 to 95% non-condensing
Operating altitude 10,000 ft. (3000 m)
(up to 45°C)
Storage altitude 15,000 ft. (4570 m)
Mean Time Between Failure (MTBF) Calculated MTBF must be greater
than 300,000 using Telcordia
SR-332, Method 1, Case 3.
Demonstrated MTBF is 500,000
hrs (with 90% confidence level)
Calculated MTBF must be greater
than 300,000 using Telcordia
SR-332, Method 1, Case 3.
Demonstrated MTBF is 500,000
hrs (with 90% confidence level)
Electromagnetic compatibility
certifications
FCC Part 15 Class A
EN 55022: 1998 (CISPR22) Class A
EN 55024: 1998 (CISPR24)
VCCI Class A
AS/NZS CISPR22 Class A
CE
MIC
GOST
China EMC certifications
BSMI (with C3K-PWR-750WAC only)
Safety certifications
UL/CSA 60950-1 first edition
EN 60950-1:2001
IEC 60950-1:2001
AS/NZS 60950-1
CE
CLEI
CCC
NOM (through partners and distributors)
Table 7 lists the acoustic specifications of the Cisco RPS 2300.
Table 7. Cisco RPS 2300 Acoustic Specifications
3
Acoustic Level (dB) Cisco RPS 2300 Power Supply Configuration
Idle Loaded
2 x C3K-PWR-1150WAC 48.9 57.7 to 66.2
2 x C3K-PWR-750WAC 51.3 59.5 to 66.7
Dimensions and Weight
Without C3K-PWR-1150WAC or C3K-PWR-750WAC power supplies:
H x W x D: 1.75 x 17.5 x 17.15 in. (4.5 x 44.5 x 43.6 cm)
Height: 1 RU
Weight: 10.8 lb (4.9 kg)
With two C3K-PWR-1150WAC power supplies:
H x W x D: 1.75 x 17.5 x 20.6 in. (4.5 x 44.5 x 52.3 cm)
Height: 1 RU
3
At ambient temperature of 35 to 55°C