Installation guide
18-18
Cisco 10000 Series Routers Line Card Hardware Installation Guide
OL-6773-04
Chapter 18 Troubleshooting the Installation
Fast Ethernet and Gigabit Ethernet Line Card Troubleshooting Information
Table 18-4 SFPs and Cisco IOS Console Messages
Situation Response/Description Console Message
No SFP module in
the system when
Cisco IOS is loaded.
The FAIL LED is not
blinking
%C10K_ALARM-6-INFO: ASSERT CRITICAL GigE1H 3/0/0 Physical
Port Link Down
%C10KGE1H-3-SFP_MISSING: Interface GigabitEthernet3/0/0, Gigabit
ethernet module (SFP) missing
%C10K_ALARM-6-INFO: ASSERT CRITICAL GigE1H 3/0/0 C10K
Gigabit Ethernet SFP module missing
The SFP module not
present followed by
SFP module
insertion.
Facility Alarm: “SFP
Missing” alarm asserted
when the SFP module is
missing, cleared when
the SFP module is
inserted,
%C10K_ALARM-6-INFO: ASSERT CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module missing
%C10K_ALARM-6-INFO: CLEAR CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module missing
%C10KGE1H-6-SFP_OK: Interface GigabitEthernet2/1/0, 1000BASE-SX
Gigabit ethernet module (SFP) inserted
A non-Gigabit
Ethernet type
Cisco-supported
SFP module is
inserted, removed,
and replaced by a
valid SFP module.
The FAIL LED will
blink as long as the
invalid SFP module
causing the error
situation is present.
%C10K_ALARM-6-INFO: ASSERT CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module bad
%C10KGE1H-3-SFP_NON_GIGE: Interface GigabitEthernet2/1/0,
Inserted module not Gigabit ethernet module (SFP)
%C10KGE1H-3-SFP_MISSING: Interface GigabitEthernet2/1/0, Gigabit
ethernet module (SFP) missing
%C10K_ALARM-6-INFO: ASSERT CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module missing
%C10K_ALARM-6-INFO: CLEAR CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module bad
%C10K_ALARM-6-INFO: CLEAR CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module missing
%C10KGE1H-6-SFP_OK: Interface GigabitEthernet2/1/0, 1000BASE-SX
Gigabit ethernet module (SFP) inserted
A non-Cisco
supported SFP
module is inserted,
removed, and a
Cisco-supported
Gigabit Ethernet
SFP module is
inserted.
The FAIL LED will
blink as long as the
invalid SFP module
causing the error
situation is present.
%C10K-4-LC_WARN: Slot[2/1] Line-card SFP eeprom vendor area CRC
check failed
%C10K_ALARM-6-INFO: CLEAR CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module missing
%C10K_ALARM-6-INFO: ASSERT CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module bad
%C10KGE1H-3-SFP_BAD_HW: Interface GigabitEthernet2/1/0, Gigabit
ethernet module (SFP) has bad HW
%C10K_ALARM-6-INFO: CLEAR CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module bad
%C10K_ALARM-6-INFO: CLEAR CRITICAL GigE1H 2/1/0 C10K
Gigabit Ethernet SFP module missing
%C10KGE1H-6-SFP_OK: Interface GigabitEthernet2/1/0, 1000BASE-SX
Gigabit ethernet module (SFP) inserted