Specifications

6
Interface Processor Installation and Configuration Guide
78-4211-02
Confirming Interface Processor Compatibility
Figure 2 Determining Compatibility from Board Part Numbers and Revision Levels
Inspecting the Physical Board
The part number and board revision are typically silk-screened along an edge of the interface processor
printed circuit board, as shown in Figure 3:
Figure 3 Diagram of Interface Processor, Board, and Carrier
Using the Show Diagbus Command
You can also use the show diagbus command to determine the part number and board revision of your
interface processor. The following is an example of a compatible CX-EIP6:
Router# show diagbus
Slot 0: Physical slot 0, ~physical slot 0xF, logical slot 0, CBus 0
Microcode Status 0x0
Master Enable, LED, WCS Loaded
Board is analyzed
EEPROM format version
1 EIP controller, HW rev 1.5, board revision B0
Serial number: 01652924 Part number: 73-0906-04
Test history: 0x00 RMA number: 00-00-00
Flags: cisco 7000 board; 7500 compatible
EEPROM contents (hex):
0x20: 01 00 01 05 00 19 38 BC 49 03 8A 04 00 00 00 00
0x30: 58 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
Slot database information:
Flags: 0x4 Insertion time: 980 (5d20 ago)
Is your
part number
suffix lower
than required?
No
Yes Yes Yes
Is your
part number
suffix equal
to required?
No
Yes
Is your
board
revision equal or
higher than
required?
Is your
part number
suffix higher
than required?
IPP upgrade required No upgrade required
No
P1124
73- 1129 - 02 REV M0
Interface processor board edge
Carrier edge
P1122