Network Configuration Parameters
• Codec[2]=G.729 (only if Bit 21 of the ConnectMode parameter is set to 0)
• Codec[3]=G.729A
If LBRCodec=3, then the Phone 2 FXS port can operate with the following codecs:
• Number of codecs=3
• Codec[0]=G.711µ-law
• Codec[1]=G.711A-law
• Codec[2]=G.729 (only if Bit 21 of the ConnectMode parameter is set to 1)
Value Type
Integer
Range
0 or 3
Default
3
Voice Configuration Menu Access Code
300
Related Parameters
ConnectMode, page 5-21 (bit 21)
AudioMode, page 5-16 (bits 1 and 17)
MediaPort
Description
Use this parameter to specify the base port where the Cisco ATA transmits and receives RTP media. This
parameter must be an even number. Each connection uses the next available even-numbered port for
RTP.
Value Type
Integer
Range
1 to 65535
Default
16384