Specifications
Appendix B Parameters and Defaults
Operating Parameters
B-14
Cisco ATA 186 Installation and Configuration Guide
OL-1267-01
SigTimer Bitmap Controls the timeouts listed.
A 32-bit value is divided into bit fields:
Call Waiting Period (bits 0-7): the
period between each burst of
call-waiting tone. Range=0 to 255 in
0.1 seconds; 0 implies the factory
default value of 100 (0x64=10 seconds)
Reorder delay (bits 8-13): the delay in
playing reorder (fast busy) tone after
far end hangs up. Range=0 to 62 in
seconds, 63=never play reorder.
Default: 5 (seconds)
Ring Timeout (bits 14-19): the amount
of time after which, when there is no
answer, the Cisco ATA 186 rejects the
incoming call. Range=0 to 63 in 10
seconds, 0=never times out. Default: 6
(60 seconds).
No Answer Timeout (bits 20-25): time
to declare no answer and initiate call
forwarding on no answer (used in SIP
only at present). Range=0 to 63 in
seconds. Default: 20 (0x14=20
seconds)
Reserved (bits 26-31).
StaticIp IP Statically assigned IP address. Used if
the DHCP parameter is set to 0.
1 0.0.0.0
StaticRoute IP Statically assigned route. Used if the
DHCP parameter is set to 0.
2 0.0.0.0
StaticSubNetMask IP Statically assigned subnetmask. Used if
the DHCP parameter is set to 0.
10 0.0.0.0
Table B-3 Common Operating Parameters and Defaults (continued)
Parameter
Value
Type Description
IVR Access
Code Default