Specifications
B-13
Cisco ATA 186 Installation and Configuration Guide
OL-1267-01
Appendix B Parameters and Defaults
Operating Parameters
Polarity Bitmap Control connect and disconnect
polarity. Possible values are:
• bit 0 (mask 0x1):
CALLER_CONNECT_
POLARITY
• bit 1 (mask 0x2):
CALLER_DISCONNECT_
POLARITY
• bit 2 (mask 0x4):
CALLEE_CONNECT_
POLARITY
• bit 3 (mask 0x8):
CALLEE_DISCONNECT_
POLARITY
304 0x00000000
PWD0, PWD1 Alpha-
numeric
string
Password for line 0 and 1. PWD0=4
PWD1=14
0
RxCodec Integer Receiving audio codec preference.
Possible values are:
• 0—G.723 (can be selected only if
LBRCodec is set to 0).
• 1—711a.
• 2—G.711u.
• 3—729a (can be selected only if
LBRCodec is set to 3).
36 0
Table B-3 Common Operating Parameters and Defaults (continued)
Parameter
Value
Type Description
IVR Access
Code Default