Datasheet
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 14
Item
Details
Yellow - BootROM has successfully loaded
Red - System failure or during boot process • ACTV- Active
Green - Active route processor
●
STBY - Standby
Yellow - Standby route processor
●
CRIT - Critical Alarm
Red - Critical alarm or during boot process
●
MAJ - Major Alarm
Red - Major alarm
●
MIN - Minor Alarm
Amber - Minor alarm
●
HD - Internal HDD
FLASH Green - Activity indicator
Off - No activity
●
USB - External Compact Flash
FLASH green - Activity indicator
●
BF - Boot Flash (Internal)
FLASH green - Activity indicator
Off - No activity
●
CARRIER
BITS I/F Mode
Off - Out of service or not configured
Green - Normal or Bridging
Amber - Fast
●
DTI Mode
Off - Warm-up, free-run, or holdover
Green - In service or working properly
Amber - Fault or loop condition
●
LINK - Management Ethernet link status
Solid green - Link with no activity
FLASH green - Link with activity
Off - No link
●
DISK2 - Internal HDD
FLASH green - Activity indicator
Off - No activity
●
CARRIER - BITS interface
Off - Out of service
Green - In frame and in service
Amber - Fault or loop condition
Physical dimensions
(H x W x D)
0.92 x 16.7 x 14.19 in. (0.02 x 0.428 x 0.36m)
Weight
5.0 lb (2.3 kg)
Approvals and compliance
Safety
●
UL60950-1 and CAN/CSA-C22.2 No. 60950-1-03 Information technology equipment
●
AS/NZS 60950-1
●
IEC/EN 60950-1 Information technology equipment
●
73/23/EEC
Electromagnetic Emissions Certification
●
CFR 47 Part 15: (FCC) Class A
●
ICES 003 Class A
●
AS/NZ CISPR 22: Class A
●
CISPR 22 (EN55022) Class A
●
VCCI Class A
●
KN22
●
IEC/EN 61000-3-2 (or 3-12 as applicable): AC Power Line Harmonics
●
IEC/EN 61000-3-3 (or 3-11 as applicable): AC Voltage Fluctuations and Flicker
Immunity
●
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV Contact, 15-kV Air)
●
IEC/EN-61000-4-3: Radiated Immunity (10 V/m)
●
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV Power, 1-kV Signal)
●
IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM)
●
IEC/EN-61000-4-5: Surge Signal Ports (1-kV indoor, 2-kV outdoor)
●
IEC/EN-61000-4-5: Surge DC Port 1-kV