Data Sheet

Data Sheet
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 13 of 22
Feature
Cisco ASA
5580-20
Cisco ASA
5580-40
Cisco ASA
5585-X with
SSP-10
Cisco ASA
5585-X with
SSP-20
Cisco ASA
5585-X with
SSP-40
Cisco ASA
5585-X with
SSP-60
USB 2.0 Ports
2
2
2
2
2
2
Serial Ports
1 RJ-45, console
1 RJ-45, console
1 RJ-45, console
and auxiliary
1 RJ-45, console
and auxiliary
1 RJ-45, console
and auxiliary
1 RJ-45, console
and auxiliary
Rack-Mountable
Yes, rails
included
Yes, rails
included
Yes, rack mounts
included
Yes, rack mounts
included
Yes, rack mounts
included
Yes, rack mounts
included
Technical Specifications
Memory
8 GB
12 GB
6 GB (SSP-10)
12 GB (SSP-10
and IPS SSP-10)
12 GB (SSP-20)
24 GB (SSP-20
and IPS SSP-20)
12 GB (SSP-40)
36 GB (SSP-40
and IPS SSP-40)
24 GB (SSP-60)
72 GB (SSP-60
and IPS SSP-60)
Minimum System Flash
1 GB
1 GB
2 GB (SSP-10)
4 GB (SSP-10
and IPS SSP-10)
2 GB (SSP-20)
4 GB (SSP-20
and IPS SSP-20)
2 GB (SSP-40)
4 GB (SSP-40
and IPS SSP-40)
2 GB (SSP-60)
4 GB (SSP 60
and IPS SSP-60)
Environmental Operating Ranges
Operating
Operating temperature
50 to 95°F (10 to 35°C)
32 to 104°F (0 to 40°C)
Relative humidity
10 to 90 percent noncondensing
10 to 90 percent noncondensing
Altitude
Designed and tested for: 0 to 10,000
ft (3050 m)
Agency approved for: 2000 m
Designed and tested for: 0 to 10,000 ft (3050 m)
Noise
55 dBa max
65 dBa max
Nonoperating
Temperature
-22 to 140°F (-30 to 60°C)
-40 to +158°F (-40 to +70°C)
Relative humidity
5 to 95 percent noncondensing
5 to 95 percent noncondensing
Altitude
0 to 30,000 ft (9144 m)
0 to 30,000 ft (9144 m)
Power
Input (per Power Supply)
Range line voltage
100 to 240 VAC
100 to 240 VAC
Normal line voltage
100 to 240 VAC
100 to 240 VAC
Max Current
12A
9A (100 VAC), 4.5A (200 VAC)
Frequency
50/60 Hz
50 to 60 Hz
Output (from Power Supply)
Steady state
800W
320W (1 SSP only)
670W (1 SSP and 1 IPS SSP)
Maximum peak
800W
370W (1 SSP only)
770W (1 SSP and 1 IPS SSP)
Maximum heat dissipation
4070 BTU/hr
3960 BTU/hr (100 VAC), 5450 BTU/hr (200 VAC)
Physical Specifications
Form Factor
4 RU, 19-in. rack-mountable
2 RU, 19-in. rack-mountable
Dimensions (H x W x D)
6.94 x 19 x 26.5 in. (17.6 x 48.3 x
67.3 cm)
3.47 x 19 x 26.5 in. (8.8x 48.3 x 67.3 cm)
Weight
66 lb (29.9 kg) with single power
supply
50 lbs (22.7 kg) with 1 SSP and single power supply
62 lbs (28.2 kg) with SSP and IPS-SSP and dual power supplies
Regulatory and Standards
Safety
UL 60950, CSA C22.2 No. 60950,
EN 60950 IEC 60950,
AS/NZS60950
UL 60950-1, CAN/CSA-C22.2 No. 60950-1
EN 60950-1, IEC 60950-1, AS/NZS 60950-1GB4943
Electromagnetic
Compatibility (EMC)
CE marking, FCC Part 15 Class A,
AS/NZS CISPR22 Class A, VCCI
Class A, EN55022 Class A,
CISPR22 Class A, EN61000-3-2,
EN61000-3-3
47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR2 2
Class A, EN55022 Class A, ICES003 Class A, VCCI Class A EN61000-3-2,
EN61000-3-3, KN22 Class A, CNS13438 Class A, EN50082-1, EN55024,
CISPR24, EN300386, KN 61000-4 Series