Datasheet

© 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 8 of 17
Feature
Cisco ASA
5506-X w/
FirePOWER
Services
Cisco ASA
5506W-X w/
FirePOWER
Services
Cisco ASA
5506H-X w/
FirePOWE
R Services
Cisco ASA
5516-X w/
FirePOWER
Services
Cisco ASA
5512-X w/
FirePOWER
Services
Cisco ASA
5515-X w/
FirePOWER
Services
Cisco ASA
5525-X w/
FirePOWER
Services
Cisco ASA
5545-X w/
FirePOWER
Services
Cisco ASA
5555-X w/
FirePOWER
Services
Acoustic
noise
Fanless
0 dBA
Fanless
0 dBA
Fanless
0 dBA
41.6 dBA
type
64.2 dBA
max
64.2 dBA
max
64.2 dBA
max
67.9 dBA
max
67.9 dBA
max
67.2 dBA
max
Non-operating Parameters
Temperature
7
-13 to
158ºF (-25
to 70ºC)
-13 to
158ºF (-25
to 70ºC)
-40 to
185ºF (-
40 to
85ºC)
-13 to
158ºF (-25
to 70ºC)
-13 to
158ºF (-25
to 70ºC)
-13 to
158ºF (-25
to 70ºC)
-13 to
158°F (-
25 to
70°C)
-13 to
158°F (-
25 to
70°C)
-13 to
158°F (-
25 to
70°C)
Relative
humidity
10 to 90
percent
nonconde
nsing
10 to 90
percent
nonconden
sing
10 to 95
percent
nonconde
nsing
10 to 90
percent
nonconde
nsing
10 to 90
percent
nonconde
nsing
10 to 90
percent
nonconde
nsing
10 to 90
percent
10 to 90
percent
10 to 90
percent
Altitude
Designed
and tested
for 0 to
15,000 ft
(4572 m)
Designed
and tested
for 0 to
15,000 ft
(4572 m)
Designed
and
tested for
0 to
15,000 ft
(4572 m)
Designed
and tested
for 0 to
15,000 ft
(4572 m)
Designed
and tested
for 0 to
15,000 ft
(4570 m)
Designed
and tested
for 0 to
15,000 ft
(4570 m)
Designed
and tested
for 0 to
15,000 ft
(457 2m)
Designed
and tested
for 0 to
15,000 ft
(4572 m)
Designed
and tested
for 0 to
15,000 ft
(4572 m)
Power Input (per power supply)
AC range line
voltage
External,
90 to 240
volts
alternating
current
(VAC)
External,
90 to 240
volts
alternating
current
(VAC)
External,
90 to 240
volts
alternatin
g current
(VAC)
External,
90 to 240
volts
alternating
current
(VAC)
100 to 240
VAC
100 to 240
VAC
100 to 240
VAC
100 to 240
VAC
100 to 240
VAC
AC normal
line voltage
90 to 240
VAC
90 to 240
VAC
90 to 240
VAC
92 to 240
VAC
100 to 240
VAC
100 to 240
VAC
100 to 240
VAC
100 to 240
VAC
100 to 240
VAC
AC current
N/A
N/A
N/A
0.25AC
amps
4.85A
4.85A
4.85A
5A, 100 to
120V
5A, 100 to
120V
2.5A, 200
to 240V
2.5A, 200
to 240V
AC frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Dual-power
supplies
None
None
None
None
None
None
None
Yes
Yes
DC domestic
line voltage
N/A
N/A
N/A
N/A
-40.5 to 56
volts direct
current
(VDC) (-
48 VDC
nominal)
-40.5 to 56
VDC (-48
VDC
nominal)
-40.5 to 56
VDC
(-48 VDC
nominal)
-40.5 to
56 VDC
-40.5 to 56
VDC
(-48 VDC
nominal)
(-48 VDC
nominal)
DC
international
line voltage
N/A
N/A
N/A
N/A
-55 to -72
VDC
-55 to -72
VDC
-55 to -72
VDC
-55 to -72
VDC
-55 to -72
VDC
(-60 VDC
nominal)
(-60 VDC
nominal)
(-60 VDC
nominal)
(-60 VDC
nominal)
(-60 VDC
nominal)
DC current
N/A
N/A
N/A
N/A
15A
(maximum
input)
15A
(maximum
input)
15A
(maximum
input)
15A
(maximum
input)
15A
(maximum
input)
Output
Steady state
12V
@2.5A
12V @2.5A
5V @3.6A
12V @
3.0A
51W
65W
75W
86W
90W
Maximum
peak
12V @ 5A
12V @ 5A
5V @4.4A
12V @
5.0A
56W
70W
108W
125W
134W