The color coding of the DC input power supply leads depends on the color coding of the DC power
source at your site. Typically, green or green/yellow is used for ground (GND), black is used for –48
V on the negative (–) terminal, and red is used for RTN on the positive (+) terminal. Ensure that the
lead color coding you choose for the DC input power supply matches the lead color coding used at
the DC power source.
Make sure that the chassis ground is connected on the chassis before you begin installing the
DC power supply. See Preventing Electrostatic Discharge Damage, page 2-2 for more information.
Procedure
Step 1 Make sure that the chassis ground is connected on the chassis before you begin installing the DC
power supply.
Step 2 Turn off the circuit breaker to the power supply.
Step 3 From the front of the chassis, verify that the power switch is in the Standby position.
Step 4 Move the circuit-breaker switch handle to the Off position, and apply tape to hold it in the Off position.
Step 5 Use a 10 gauge wire-stripping tool to strip each of the three wires coming from the DC input power
source. Strip the wires to 0.27 inch (7 mm) +
0.02 inch (0.5 mm). Do not strip more than the
recommended length of wire because doing so could leave the wire exposed from the DC power supply
connection. (See Figure 4-22.)
Figure 4-22 Stripping the DC Input Power Source Wire
Warning
An exposed wire lead from a DC input power source can conduct harmful levels of electricity. Be sure
that no exposed portion of the DC input power source wire extends from the terminal block plug.
Statement 122
Step 6 Identify the positive, negative, and ground feed positions for the DC power supply connection. The
recommended wiring sequence is as follows (see Figure 4-23 on page 4-19):
Ground lead wire (middle)
Positive (+) lead wire (left)
Negative (–) lead wire (right)
1 We recommend that you strip the wire to 0.27 inch (7 mm).
333062
1