Installation guide
33
Cisco AS5850 Universal Gateway Commissioning Guidelines
78-10537-04
How to Commission the Cisco AS5850 Universal Gateway
Step 4 Specify the T1 controller you want to configure.
Gateway(config)# controller t1 1/0
or
Gateway(config)# controller t3 7/0:16
or
Specify the E1 controller you want to configure.
Gateway(config)# controller e1 1/0
or, for Sonet controller
Router(config)# controller E1
slot
/
port.path:E1 contoller
Note When you configure the CT1 or CE1 controller, a corresponding D channel serial interface is
created automatically.
Step 5 Specify the PRI channels.
Gateway(config-controller)# pri-group [timeslots
range
]
Note For CT1 ISDN PRI—If you do not specify the time slots, the specified controller is configured
for 23 B channels and 1 D channel. B channel numbers range from 1 to 23; channel 24 is the D
channel for T1. Corresponding serial interface numbers range from 0 to 23. In commands, the D
channel is interface serial slot/port:23—for example, interface serial 1/0:23.
For CE1 ISDN PRI—If you do not specify the time slots, the specified controller is configured
for 30 B channels and 1 D channel. B channel numbers range from 1 to 31; channel 16 is the D
channel for E1. Corresponding serial interface numbers range from 0 to 30. In commands, the D
channel is interface serial slot/port:15—for example, interface serial 1/0:15.
Step 6 Return to privileged EXEC mode.
Gateway(config-controller)# Ctrl-Z
Gateway#
Step 7 Verify that the controllers are up and no alarms or errors are detected. Error counters are recorded over
a 24-hour period in 15-minute intervals. In the display output, focus on the data in the current interval.
Gateway# show controller t3
T3 0/0 is up.
Applique type is Channelized T3
No alarms detected.
FEAC code received: No code is being received
primary-5ess AT&T 5ESS switch type for the United States
primary-dms100 NT DMS-100 switch type for the United States
primary-ni National ISDN switch type
Table 5 ISDN Switch Types (continued)
Area Keyword Switch Type