Installation guide

18
Cisco AS5850 Universal Gateway Commissioning Guidelines
78-10537-04
How to Commission the Cisco AS5850 Universal Gateway
To inspect the file system, perform the following steps as appropriate for your system.
Step 1 View the different file storage areas and file management functions. Additionally, verify that you have
everything you ordered from manufacturing, such as flash memory. The asterisk (*) near the bottom of
the output indicates the current directory.
AS5850# show file systems
File Systems:
Size(b) Free(b) Type Flags Prefixes
31916032 14307328 flash rw disk0:
- - network rw rcp:
- - opaque rw null:
- - opaque rw system:
- - network rw tftp:
520184 481796 nvram rw nvram:
* 15990784 11484640 flash rw bootflash: flash:
- - network rw ftp:
AS5850#
Step 2 Display the objects in the system memory directory:
AS5850# dir system:
Directory of system:/
1 -rw- 51613 <no date> running-config
2 dr-x 0 <no date> memory
12 dr-x 0 <no date> vfiles
No space information available
AS5850#
Note Remember to include the trailing colon (:) in the dir commands.
Step 3 Inspect the flash memory. As the chassis boots up, the image is copied, decompressed, and loaded into
DRAM memory.
AS5850# pwd
disk0:
AS5850# dir
Directory of disk0:/
3 -rw- 325539 Jan 01 2000 04:33:44 np_6_83_2.spe
83 -rw- 8987568 Jan 02 2000 02:45:30 c5850-p6-mz.Aug23
2278 -rw- 8617256 Jan 01 2000 00:17:16 c5850-p6-mz.Sep5
31916032 bytes total (13299712 bytes free)
bootflash: Flash memory on the route-switching module.
nvram: Nonvolatile configuration memory.
Table 1 Memory Descriptions (continued)
Component Description