Chapter 2 Commissioning
Task 1. Verifying Basic Setup
The following system message and prompt appears.
--- System Configuration Dialog ---
Would you like to enter the initial configuration dialog? [yes/no]: no
Because the NAS has never been configured, the Cisco IOS software cannot find a startup-config
file. In this example, the Cisco IOS software is configured manually. The automatic setup script is
not used.
00:00:52: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 12 Succeeded
00:00:53: %DSC_REDUNDANCY-3-BICLINK: Switching to DSC 12
00:00:56: %DSC_REDUNDANCY-3-BICLINK: Link to active DSC up
00:02:05: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 0 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 2 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 3 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 4 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 5 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 6 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 7 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 8 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 9 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 10 Succeeded
Press RETURN to get started!
5800>
By using DSIP, the router shelf detects the state of each card in the dial shelf.
Depending on the number of cards in the dial shelf, there is a delay of 60 to 120 seconds before the
DSIP Hello messages are displayed on your terminal session.
After powering up the Cisco AS5800, enter the show environment command. Verify that there are
no critical grounding, heating, or power problems. The following shows an operating environment.
5800-NAS> show environment
All measured values are normal
5800-NAS> show environment all
Power Supplies:
Power supply 1 is empty.
Power supply 2 is Zytek AC Power Supply. Unit is on.
Temperature readings:
chassis inlet measured at 25C/77F
chassis outlet 1 measured at 27C/80F
chassis outlet 2 measured at 33C/91F
chassis outlet 3 measured at 41C/105F
Voltage readings:
+3.45 V measured at +3.49 V
+5.15 V measured at +5.21 V
+12.15 measured at +12.34 V
-11.95 measured at -11.81 V
Envm stats saved 1 time(s) since reload
5800-NAS>