Specifications

Table Of Contents
5-6
Cisco AS5800 Operations, Administration, Maintenance, and Provisioning Guide
DOC-7810814=
Chapter 5 Maintenance
Replacement Procedures
Step 7 Grasp the handle and carefully pull the PEM from the backplane connectors using a gentle rocking
motion; then remove the PEM from the DC power supply chassis. (See Figure 5-5.)
Figure 5-5 Removing and Replacing a PEM
This completes the PEM removal process. Continue with Replacing the Power Entry Module, page 5-6.
Replacing the Power Entry Module
To install a new PEM, complete the following steps. (See Figure 5-5 to locate the PEMs in the dial shelf.)
Step 1 Grasp the PEM handle and carefully align the PEM with the DC-input power supply bay.
Step 2 Slide the PEM into the power supply bay until it is fully seated and connected to the backplane
connectors.
Step 3 Using a 1/4-in. flat-blade screwdriver, tighten the captive screws on the PEM front panel.
Step 4 Plug the alarm cables into the bell alarm terminal block. (See Figure 5-5.)
This completes the procedure for replacing a PEM in the dial shelf. To connect the PEM power cables
and power on the PEM, continue with section Connecting to Your DC Power Source.
Note If you are connecting to an AC power source, continue with section Connecting to an AC
Power Source.
LEDs
4
8
V
4
8
V
R
T
N
C
N
C
N
O
POW
ER
MISWIRE
C
N
C
N
O
POWER
MISWIRE
4
8
V
4
8
V
R
T
N
H11077
DC-input power
terminal block
Captive
screw
Captive
screw
Bell alarm
terminal block
Filter module
PEM