Specifications
Chapter 13 Diagnostics and Troubleshooting
Checking Basic Settings
13-42
Cisco Aironet Access Point Software Configuration Guide
OL-0657-07
Note Draft standard 8 is the default setting in firmware version 11.05 and earlier,
and it might remain in effect when you upgrade the firmware to version 11.06
or later. Check the setting on the Authenticator Configuration page in the
management system to make sure the best draft standard for your network is
selected.
Use the Authenticator Configuration page to select the draft of the 802.1X
protocol the access point’s radio should use. Follow these steps to set the draft for
your access point:
Step 1 Browse to the Authenticator Configuration page in the access point management
system.
a. On the Summary Status page, click Setup.
b. On the Setup page, click Security.
c. On the Security Setup page, click Authentication Server.
Table 13-4 802.1X Protocol Drafts and Compliant Client Firmware
Firmware Version Draft 7 Draft 8 Draft 10
PC/PCI cards 4.13 — x —
PC/PCI cards 4.16 — x —
PC/PCI cards 4.23 — x —
PC/PCI cards 4.25 and later —— x
WGB34x/352 8.58 — x —
WGB34x/352 8.61 or later —— x
AP34x/35x 11.05 and earlier — x —
AP34x/35x 11.06 and later
1
1. The default draft setting in access point and bridge firmware version 11.06
and later is Draft 10.
— xx
BR352 11.06 and later
1
— xx