Specifications
Chapter 8 Security Setup
Setting Up EAP Authentication
8-22
Cisco Aironet Access Point Software Configuration Guide
OL-0657-07
Note Draft standard 8 is the default setting in firmware version 11.05 and
earlier, and it might remain in effect when you upgrade the firmware
to version 11.06 or later. Check the setting on the Authenticator
Configuration page in the management system to make sure the best
draft standard for your network is selected.
Step 3 Enter the name or IP address of the RADIUS server in the Server Name/IP entry
field.
Step 4 Enter the port number your RADIUS server uses for authentication. The default
setting, 1812, is the port setting for Cisco’s RADIUS server, the Cisco Secure
Access Control Server (ACS), and for many other RADIUS servers. Check your
server’s product documentation to find the correct port setting.
Step 5 Enter the shared secret used by your RADIUS server in the Shared Secret entry
field. The shared secret on the access point must match the shared secret on the
RADIUS server. The shared secret can contain up to 64 alphanumeric characters.
Step 6 Enter the number of seconds the the access point should wait before
authentication fails.
Table 8-3 802.1X Protocol Drafts and Compliant Client Firmware
Firmware Version Draft 7 Draft 8 802.1x-2001
PC/PCI cards 4.13 — x —
PC/PCI cards 4.16 — x —
PC/PCI cards 4.23 — x —
PC/PCI cards 4.25 and later —— x
WGB34x/352 8.58 — x —
WGB34x/352 8.61 or later —— x
AP34x/35x 11.05 and earlier — x —
AP34x/35x 11.06 and later
1
1. The default draft setting in access point and bridge firmware version 11.06 and later is
802.1x-2001.
— xx
BR352 11.06 and later
1
— xx