Specifications
4-14
Cisco Aironet 1520 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-11321-08
Chapter 4 Cisco Aironet 1140 Series Lightweight Access Points
Channels and Maximum Power Levels
Ta b l e 4-11 5-GHz Channels and Maximum Conducted Power in the –K (South Korea) Regulatory Domain
HW Group 1
Non HT20
Single Antenna
6 to 54 Mbps
HW Group 1
Non HT40
Duplicate
Single Antenna
6 to 54 Mbps
HW Group 2
Non HT20
Dual Antennas
M0 to M15
HW Group 1
Non HT20
Dual Antennas
M0 to M15
BW Band Freq (MHz) CH id Tx 1 Tx 2 Total
Power
Tx 1 Tx 2 Total
Power
Tx 1
Tx 2
Total
Power
Tx 1 Tx 2 Total
Power
40 UNII-1 5180 36 17 Off 17 – – – 13 13 16 – – –
40 5200 40 17 Off 17 – – – 13 13 16 – – –
40 5220 44 17 Off 17 – – – 13 13 16 – – –
40 5240 48 17 Off 17 – – – 13 13 16 – – –
40 UNII-2 5260 52 17 Off 17 – – – 17 17 20 – – –
40 5280 56 17 Off 17 – – – 17 17 20 – – –
40 5300 60 17 Off 17 – – – 17 17 20 – – –
40 5320 64 17 Off 17 – – – 17 17 20 – – –
40 UNII-2
ext
5500 100 17 Off 17 – – – 17 17 20 – – –
40 5520 104 17 Off 17 – – – 17 17 20 – – –
40 5540 108 17 Off 17 – – – 17 17 20 – – –
20 5560 112 17 Off 17 – – – 17 17 20 – – –
20 5580 116 17 Off 17 – – – 17 17 20 – – –
20 5600 120 17 Off 17 – – – 17 17 20 – – –
20 5620 124 17 Off 17 – – – 17 17 20 – – –
20 5640 128 Not allowed – – – Not allowed – – –
20 5660 132 Not allowed – – – Not allowed – – –
20 5680 136 Not allowed – – – Not allowed – – –
20 5700 140 Not allowed – – – Not allowed – – –
20 UNI-3 5745 149 17 Off 17 – – – 17 17 20 – – –
20 5765 153 17 Off 17 – – – 17 17 20 – – –
20 5785 157 17 Off 17 – – – 17 17 20 – – –
20 5805 161 17 Off 17 – – – 17 17 20 – – –
20 5.8
ISM
5825 165 Not allowed – – – Not allowed – – –
40 UNII-1 5180 & 5200 36, 40u, or 40, 36L – – – 17 Off 17 – – – 16 16 19
40 5220 & 5240 44, 48U, or 48, 44L – – – 17 Off 17 – – – 16 16 19
40 UNII-2 5260 & 5280 52, 56U, or 56, 52L – – – 17 Off 17 – – – 17 17 20
40 5300 & 5320 60, 64U, or 64, 60L – – – 17 Off 17 – – – 17 17 20
40 UNII-2
ext
5500 & 5520 100, 104U, or 104, 100L – – – 17 Off 17 – – – 17 17 20
40 5540 & 5560 108, 112U, or 112, 108L – – – 17 Off 17 – – – 17 17 20
40 5580 & 5600 116, 120U, or 120, 116L – – – 17 Off 17 – – – 17 17 20
40 5620 & 5640 124, 128U, or 128, 124L – – – Not allowed – – – Not allowed
40 5660 & 5680 132, 136U, or 136, 132L – – – Not allowed – – – Not allowed
40 UNI-3 5745 & 5765 149, 153, or 153, 149L – – – 17 Off 17 – – – 17 17 20
40 5785 & 5805 157, 161U, or 161, 157L – – – 17 Off 17 – – – 17 17 20