Specifications
2-556
Catalyst 4500 Series Switch Cisco IOS Command Reference—Release IOS XE 3.3.0XO(15.1(1)XO)
OL_28738 -01
Chapter 2 Cisco IOS Commands for the Catalyst 4500 Series Switches
show environment
show environment
To display the environment alarm, oper ational status, and current reading for the cha ssis, use the show
environment command.
show env iro nm ent [alarm] | [status [c hassis | fantra y | powersupply | supervisor]] |
[temperature]
Syntax Description
Defaults T his command has no default settings.
Command Modes Privileged EXE C mode
Examples This exampl e shows how to display informa tion about the environme nt alarms, operationa l status, and
current temperature readings for the chassis:
Switch# show environment
no temperature alarms
Module Sensor Temperature Status
------+--------------------------+--------------------+------------
1 Air inlet 38C (56C,68C,71C) ok
1 Air inlet remote 32C (46C,59C,62C) ok
1 Air outlet 44C (66C,76C,79C) ok
1 Air outlet remote 37C (60C,71C,74C) ok
3 XPP 60C (85C,90C,95C) ok
3 IFE 38C (85C,90C,95C) ok
3 CONAN 48C (85C,90C,95C) ok
3 CPU 50C (85C,90C,95C) ok
4 XPP 76C (85C,90C,95C) ok
4 IFE 44C (85C,90C,95C) ok
4 CONAN 53C (85C,90C,95C) ok
4 CPU 53C (85C,90C,95C) ok
7 air inlet 32C (45C,60C,70C) ok
7 air outlet 37C (61C,76C,86C) ok
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-1300ACV AC 1300W good good good
PS2 none -- -- -- -- --
Power supplies needed by system : 1
alarm (Optional) Specifies the alarm status of the chassis.
status (Optional) Specifies the operational status information.
chassis (Optional) Specifies the operational status of the chassis.
fantray (Optional) Specifies the status of the fan tray, and shows fan tray power consumption.
powersupply (Optional) Specifies the status of the power supply.
supervisor (Optional) Specifies the status of the supervisor engine.