Datasheet
© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 8
Specification
Value
Notes
Intermodulation
●
CTB
●
CSO
≥ 58 dBc
≥ 58 dBc
4
Interstage equalizer
0 to 15 dB
Output return loss
≥ 20 dB
5
Test point, outputs
-20±0.5 dB @ 45 to 862 MHz
-20±0.75 dB @ 45 to 1002 MHz
Frequency range
5 to 200 MHz
6
Insertion loss
4±0.5 dB @ 5 to 65 MHz
≤ 6 dB @ 65 to 200 MHz
7
Input return loss
≥ 20 dB
8
Test point, outputs
Connected to Rev. Tx Transmitter
9
Isolation, reverse switch in off position
> 55 dB @ 5 to 65 MHz
> 45 dB @ 65 to 200 MHz
Three-state reverse switch (ingress)
On/–6 dB/off
Table 2. General Specifications
Specification
Value
Notes
Hum modulation
≤ –65 dB
Transient protection
6 kV, 1, 2 µs/50 µs
Screening effectiveness
≥ 85 dB
Power Supply
Supply voltage
Mains powered
Network powered
187 to 250 VAC, 50 to 60 Hz
24 to 65 VAC
Power consumption
General without plug-ins
Compact transponder
FP reverse Tx
DFB reverse Tx
≤ 30W
≤ 2.0W
≤ 2.5W
≤ 3.0W
10
Maximum current, outputs
7 A AC
Maximum current, external supply
15 A AC
11
Safety and Compliance
Electrical safety
EN 50083-1, EN 60065, IEC 65
EMC emissions
EN 50083-2
Connectors
RF outputs
PG11
RF test points
F-connector
Optical adapter
●
Standard
●
Optional
SC/APC to SC/APC
SC/APC to E2000
12
LCI interface
Mini jack, female
Mechanics
A90100, Indoor Use
A90300, Outdoor Use
Housing
Die-cast, aluminum
Water and dust ingress rating
IP54
IP68