Datasheet
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 12 of 14
Description
Cisco ASR 901 Specifications
Power rating
1 GE models:
●
DC-input voltage rating: 24 VDC, -48 VDC, -60 VDC
●
DC-input current rating: 2.5A maximum for non-TDM variants and 3.0A maximum for TDM variants
10 GE models:
●
DC-input voltage rating: 24 VDC, -48 VDC, -60 VDC
DC-input current rating: 4A maximum
Power connector
6-position 2-tier stacked connector comprising two feeds, A and B DC power (AMPHENOL ELVA06100), and
3-position mating connectors for each feed (AMPHENOL ELVP03100)
●
AC power: AC voltage = 220V, Temp = 65C, Traffic -> 8 copper (1 GE) port + 4 SFP (GE) +2 SFP+ (10 GE)
+ 8 TDM ports
●
DC power: DC voltage = 48V, Temp = 65C, Traffic -> 8 copper (1 GE) port + 4 SFP (GE) +2 SFP+ (10 GE)
+ 8 TDM ports
●
Traffic conditions are the same for the AC and DC chassis. In the case of Ethernet-only chassis, TDM,
traffic is not present
Table 9. Environmental Specifications
Description
Cisco ASR 901
Operating temperature
1
-40 to 149°F (-40 to 65°C)
Nonoperating temperature
-40 to 158°F (-40 to 70°C)
Relative humidity
10% to 85%, noncondensing, ±5 %
Operational altitude
13,000 ft (4000m) maximum 104°F (40°C) ambient
Acoustic noise
2
1 GE models: 66 dBA with 23 cfm fan
10 GE models: 61 dBA with 19 cfm fan
Air flow
1 GE models: 46 cfm
10 GE models: 57 cfm
1
Optics used may limit the temperature range.
2
The above are for normal (nonfailure) operation. When operating with a fan failure, the above may be exceeded.
Table 10. Safety and Compliance
Type
Standards
Safety
●
UL/CSA 60950-1
●
IEC/EN 60950-1
●
AS/NZS 60950.1
EMC emissions
●
FCC 47CFR15, Class A
●
EN55022, Class A
●
CISPR 22, Class A
●
AS/NZS CISPR 22, Class A
●
ICES 003, Class A
●
VCCI, Class A
●
KN 22, Class A
EMC immunity
●
EN/IEC61000-4-2 Electrostatic Discharge Immunity - Enclosure
●
EN/IEC61000-4-3 Radiated Immunity - Enclosure
●
EN/IEC61000-4-4 Electrical Fast Transient Immunity
●
EN/IEC61000-4-5 Surge
●
EN/IEC61000-4-6 Immunity to Conducted Disturbances