Spec Sheet Cisco UCS C460 M2 High-Performance Rack-Mount Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.
CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Chassis Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 BASE SERVER STANDARD CAPABILITIES and FEATURES . .
OVERVIEW OVERVIEW The Cisco UCS C460 M2 High-Performance Rack Server (Figure 1) is a four-rack-unit (4RU) server supporting the Intel® Xeon® processor E7-4800 and E7-8800 product families, with up to 1 terabyte (TB) of double-data-rate 3 (DDR3) memory in 64 slots, and up to 12 small form factor (SFF), hot-pluggable SAS and SATA disk drives. 10 PCI Express (PCIe) slots support the Cisco UCS C-Series network adapters, with an eleventh PCIe slot reserved for a hard disk drive array controller card.
DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS C460 M2 General-Purpose Rack Server. Figure 2 Chassis Front View 3 4 5 6 7 8 9 10 198383 2 1 1 HDDs (up to 12) 6 CPU status LED 2 SATA DVD drive 7 Network activity LED 3 Fans (up to 8) 8 Operations panel (see Figure 3 on page 5 for a detailed view) 4 Power supply status LED 9 VGA connector 5 Memory status LED 10 USB ports (3) Figure 3 is a detailed view of operator panel.
DETAILED VIEWS Figure 3 Chassis Front View 3 2 5 4 6 7 8 9 197617 1 1 ID LED 6 Power status LED 2 ID button 7 Power button 3 HDD fault LED 8 Reset button 4 System health LED 9 NMI button 5 Fan fault LED Cisco UCS C460 M2 High-Performance Rack-Mount Server 5
DETAILED VIEWS Chassis Rear View Figure 4 shows the external features of the rear panel.
BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER on page 10.
BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features (continued) Capability/Feature Storage controller Description Factory-configured RAID support options: ■ RAID 0, 1, 5, 6, 10, 50, and 60 support for up to 12 SAS or SATA drives with either the optional LSI MegaRAID SAS 9260-8i controller, or ■ RAID 0 and 1 support for up to 8 SAS or SATA drives with the optional LSI MegaRAID 9240-8I RAID controller.
BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features (continued) Capability/Feature Power subsystem Description ■ ■ Either 2 or 4 850 W power supplies Power supplies are hot-swappable, rear-accessible, and redundant as 2+2 or 3+1 NOTE: You can use 2 power supplies with a 2-CPU configuration. In this case, 1+1 redundancy is supported only if your server’s overall power consumption can be supported by a single 850W power supply during the failure and hot-swap.
CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C460 M2 High-Performance Rack Server: 10 ■ STEP 1 VERIFY BASE SKU, page 11 ■ STEP 2 CHOOSE CPU(S), page 12 ■ STEP 3 CHOOSE MEMORY, page 13 ■ STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs, page 18 ■ STEP 5 CHOOSE RAID CONFIGURATION, page 20 ■ STEP 6 CHOOSE PCIe OPTION CARD(S), page 22 ■ STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 25 ■ STEP 8 ORDER POWER SUPPLIES, page 28 ■ STEP 9 SE
CONFIGURING the SERVER STEP 1 VERIFY BASE SKU Verify the product ID (PID) of the base server as shown in Table 2.
CONFIGURING the SERVER STEP 2 CHOOSE CPU(S) The standard CPU features are: ■ Intel Xeon E7-8800 or E7-4800 (Westmere EX) series CPUs ■ Intel 7500 chipset and Intel 7510 scalable memory buffer ■ Cache size of 18, 24, or 30 MB Choose CPUs The available CPUs are listed in Table 3. Table 3 Available CPUs: Intel Xeon Westmere E7-48xx/88xx Family Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI Highest DDR3 DIMM Clock Support (MHz) UCS-CPU-E78837 E7-8837 2.
CONFIGURING the SERVER STEP 3 CHOOSE MEMORY The standard memory features are: ■ ■ ■ Plug-In Memory Riser Boards — Up to eight DIMMs per riser board — Riser boards plug vertically into the motherboard — Up to two riser boards per CPU (total maximum of eight per system) DIMMs — Clock speed: 1066 MHz — Ranks per DIMM: 2 or 4 — Operational voltage: 1.5 or 1.35 V — Registered Each CPU controls four serial memory interface (SMI) channels.
CONFIGURING the SERVER Figure 5 14 C460 M2 Memory Organization Cisco UCS C460 M2 High-Performance Rack-Mount Server
CONFIGURING the SERVER Choose Memory Riser Boards You may choose four memory riser boards for a two-CPU system or eight memory riser boards for a four-CPU system. Table 4 Available Memory Riser Boards Product ID (PID) PID Description Max DIMMs per Riser Memory riser board for C460 m2 server only 8 Riser Board Options UCSC-MRB-002-C460 Approved Configurations (1) Two-CPU System ■ Choose four memory riser boards from Table 4. (1) Four-CPU System ■ Choose eight memory riser boards from Table 4.
CONFIGURING the SERVER DIMMs are orderable as kits, with two DIMMs per kit. Choose the desired number of DIMMs and the memory mirroring option if desired. The available memory DIMMs are listed in Table 5. Table 5 Available DDR3 DIMM Kits (2 DIMMs per Kit) Product ID (PID) PID Description Voltage (V) Ranks/D IMM DIMM Options UCS-MR-2X041RX-C 2X4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x1/1.35v 1.5/1.35 1 A02-M308GB3-2 8GB DDR3-1333MHz RDIMM/PC3-10600/2x4GB 2R Kit/Low Volt 1.5/1.
CONFIGURING the SERVER ■ Eight memory risers with at least two matched DIMM pairs per riser (16 DIMMs total) and up to four matched DIMM pairs per riser (64 DIMMs total). NOTE: There are three memory mirroring modes: 1 Intra-socket mirroring 2 Inter-socket cross-memory-controller mirroring 3 Inter-socket complete master-slave mirroring Mirroring mode can be configured using the UCS Manager BIOS Policy RAS Memory tab Caveats ■ Each CPU controls four DDR3 channels.
CONFIGURING the SERVER STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs The standard disk drive features are: ■ 2.5-inch small form factor ■ Hot-pluggable ■ Sled-mounted Choose Drives The available drives are listed in Table 6.
CONFIGURING the SERVER ■ Select up to 8 SAS or SATA drives listed in Table 6 (you can mix SAS/SATA drives, but not HDD/SSD drives). This configuration supports RAID 0and 1. Caveats ■ You cannot mix HDDs and SSDs.
CONFIGURING the SERVER STEP 5 CHOOSE RAID CONFIGURATION The C460 M2 server accommodates either an LSI MegaRAID SAS 9260-8i or LSI MegaRAID SAS 9240-8i RAID controller. The C460 M2 contains a drive bay housing up to 12 HDDs or SSDs. Cisco can provide factory-configured RAID 0, 1, 5, 6, and 10 systems depending on the RAID implementation chosen, the RAID controller chosen, and the number of drives ordered. Factory-configured RAID options are listed at the end of Table 7.
CONFIGURING the SERVER Table 7 Available RAID Options (continued) Product ID (PID) PID Description R2XX-RAID5 Factory pre-configured RAID option Enable RAID 5 Setting. Requires minimum 3 drives of same size, speed, capacity. R2XX-RAID6 Factory pre-configured RAID option Enable RAID 6 Setting. Requires minimum 4 drives of same size, speed, capacity. R2XX-RAID10 Factory pre-configured RAID option Enable RAID 10 Setting.
CONFIGURING the SERVER STEP 6 CHOOSE PCIe OPTION CARD(S) The standard PCIe card offerings are: ■ Converged Network Adapters (CNA) ■ Network Interface Cards (NICs) ■ Host Bus Adapters (HBAs) Choose PCIe Option Cards The available PCIe option cards are listed in Table 8.
CONFIGURING the SERVER Use Table 9 as a guide for adding PCIe cards. See Figure 6 for the slot locations.
CONFIGURING the SERVER Caveats ■ CPU3 must be installed to support PCIe slots 5, 6, 7, 9, and 10. ■ Legacy I/O devices such as video cards are only supported on slots 1, 2, 3, 4 and 8. ■ The Cisco Card NIC mode is currently supported only with a Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01) that is installed in PCIe slot 1. ■ The C460 server accommodates two P81E Virtual Interface cards (VICs). These cards are supported only in slots 1 and 2.
CONFIGURING the SERVER STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server. Choose Optional Twinax Cables Copper twinax cables are listed in Table 10. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.
CONFIGURING the SERVER Choose Optional SFP Modules Optical Cisco SFP+ modules are listed in Table 11. Table 11 Available SFP Modules Product ID (PID) PID Description SFP-10G-SR 10GBASE-SR SFP Module 850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring Approved Configurations (1) Choose Up to Two SFP+ Modules for Each Network Card Ordered ■ You may choose one or two SFP+ optical modules cables for each network card ordered.
CONFIGURING the SERVER Figure 7 Network Card Connections Cisco UCS C460 M2 High-Performance Rack-Mount Server 27
CONFIGURING the SERVER STEP 8 ORDER POWER SUPPLIES If you ordered a 2-CPU system, the base server comes with two power supplies, which is adequate to power the server. If you ordered a 4-CPU system, you must order two additional power supplies, listed in Table 14.
CONFIGURING the SERVER STEP 9 SELECT AC POWER CORD(s) Select the appropriate AC power cords listed in Table 13. You may select a minimum of no power cords and a maximum of two power cords. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
CONFIGURING the SERVER Table 13 Available Power Cords PID Description Images SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China Plug: EL 218 (CCEE GB2009) Cordset rating 10A, 250V (2500 mm) Connector: EL 701 (IEC60320/C13) Power Cord, 250VAC 10A CEE 7/7 Plug, EU Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.
CONFIGURING the SERVER Table 13 Available Power Cords Product ID (PID) PID Description CAB-9K12A-NA Power Cord, 125VAC 13A NEMA 5-15 Plug, North America CAB-C13-C14-2M Power Cord Jumper, C13-C14 Connectors, 2 Meter Length CAB-JPN-3PIN Power Cord 3PIN, Japan Cisco UCS C460 M2 High-Performance Rack-Mount Server Images Image not available 31
CONFIGURING the SERVER STEP 10 ORDER OPTIONAL CABLE MANAGEMENT ARM A tool-less slide rail kit (PID RC460-SLDRAIL) is included with the C460 M2 server. The cable management arm attaches to the left and right slide rails at the rear of the server and is used for cable management. You can order the cable management arm listed in Table 14.
CONFIGURING the SERVER STEP 11 ORDER OPTIONAL INTERNAL FLASH eUSB DRIVE One or two optional 2 GB eUSB drives may be ordered and used as a boot drive. The eUSB drives plug into vertical USB slots on the motherboard. You can order the eUSB boot drive listed in Table 15. Table 15 Available USB Drive Product ID (PID) PID Description Drive Type Capacity RC460-EUSB 2 GB eUSB Drive USB 2 GB Approved Configurations ■ Select one or two eUSB drives from Table 15.
CONFIGURING the SERVER STEP 12 ORDER A TRUSTED PLATFORM MODULE Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy.
CONFIGURING the SERVER STEP 13 CHOOSE OPERATING SYSTEM Several operating systems are available from which to choose. Choose one of the operating systems listed in Table 17.
CONFIGURING the SERVER Table 17 Operating Systems (continued) PID Description Product ID (PID) RHEL-SFS-2S-1A-RS RHEL Option/Scalable File Sys/2 Socket/1 Yr Redhat Svcs Incl RHEL-HA-2S-3A-RS RHEL Option/High-Availability/2 Socket/3Yr Redhat Svcs Incld RHEL-RS-2S-3A-RS RHEL Option/Resilient Storage/2 Socket/3 Yr Redhat Svcs Incl RHEL-SFS-2S-3A-RS RHEL Option/Scalable File Sys/2 Socket/3 Yr Redhat Svcs Incl Windows Server MSWS-08-STHV Windows Svr 2008 ST media (1-4CPU, 5CAL) MSWS-08-ENHV Windo
CONFIGURING the SERVER STEP 14 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 18.
CONFIGURING the SERVER STEP 15 CHOOSE OPTIONAL VALUE-ADDED SOFTWARE You can select from a variety of value-added software listed in Table 18.
CONFIGURING the SERVER STEP 16 CHOOSE SERVICE and SUPPORT LEVEL A variety of service options are available, as described in this section. Unified Computing Warranty, No Contract If you have noncritical implementations and choose to have no service contract, the following coverage is supplied: ■ Three-year parts coverage. ■ Next business day (NBD) parts replacement eight hours a day, five days a week. ■ 90-day software warranty on media. ■ Downloads of BIOS, drivers, and firmware updates.
CONFIGURING the SERVER optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in Table 21.
CONFIGURING the SERVER Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention (UCDR) service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
CONFIGURING the SERVER Table 23 Drive Retention Service Options (continued) Service Description UCS Warranty Plus With Drive Retention Service Program Name Service Level GSP Service Level Product ID (PID) UC PLUS DR UCWD2 8x5x4 CON-UCWD2-C460-M2SFF UCWD3 24x7x4 CON-UCWD3-C460-M2SFF UCWD4 24x7x2 CON-UCWD4-C460-M2SFF UCWD5 8x5xNBD Onsite CON-UCWD5-C460-M2SFF UCWD6 8x5x4 Onsite CON-UCWD6-C460-M2SFF UCWD7 24x7x4 Onsite CON-UCWD7-C460-M2SFF UCWD8 24x7x2 Onsite CON-UCWD8-C460-M2SFF For
OPTIONAL STEP - ORDER RACKS OPTIONAL STEP - ORDER RACKS The optional R42610 rack is available from Cisco for the C-Series servers, including the C460 M2 server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in Table 24. Racks are shipped separately from the C460 M2 server.
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC460 M2 server. This PDU is available in a zero rack unit (RU) style (see Table 24). Table 25 PDU Options Product ID (PID) PID Description RP208-30-2P-U-2 Zero RU PDU For more information about the PDU, see PDUs on page 50.
SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C460 M2 chassis with the top cover removed is shown in Figure 8.
SUPPLEMENTAL MATERIAL CPUs and DIMMs Physical Layout Each CPU controls four serial memory interface (SMI) channels (see Figure 5 on page 14). There is one memory riser for every two channels. There are therefore two memory risers per CPU. Each CPU channel drives a memory buffer on a riser card, and each memory buffer converts a CPU SMI into two DDR3 subchannels that each read and write two DIMM pairs on a memory riser. The physical layout of a memory riser is shown in Figure 9.
SUPPLEMENTAL MATERIAL ■ The DIMMs in any given pair must be identical. ■ Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes inaccessible. ■ For optimal performance, distribute DIMMs evenly across all installed CPUs and memory buffers. ■ DIMMs within a subchannel are populated starting with the DIMMs farthest from the memory buffer in a fill-farthest approach.
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 10) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: ■ Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are listed in Table 26. Table 26 Cisco R42610 Rack Specifications Parameter Standard Rack Expansion Rack Dimensions (H x W x D) 78.
SUPPLEMENTAL MATERIAL Figure 10 Cisco R42610 Rack Front view - door closed Front view - door open Cisco UCS C460 M2 High-Performance Rack-Mount Server Front view - door removed 49
SUPPLEMENTAL MATERIAL PDUs Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection. Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician. With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 27 UCS C460 M2 Dimensions and Weight1 Parameter Value Height 6.8 in. (174 mm) Width 16.7 in.(424 mm) Depth 27.7 in. (704 mm) Front Clearance 3 in. (7.62 cm) Side Clearance 1 in. (25.4 mm) Rear Clearance 6 in. (152.4 mm) Weight (maximum configuration, including slide rail brackets and cable management arm) 110.23 lbs (50 kg)* Notes . . . 1.
TECHNICAL SPECIFICATIONS Environmental Specifications The power specifications for the C460 M2 server are listed in Table 29.
TECHNICAL SPECIFICATIONS Cisco UCS C460 M2 High-Performance Rack-Mount Server 53
TECHNICAL SPECIFICATIONS 54 Cisco UCS C460 M2 High-Performance Rack-Mount Server