Technical data
42 Known limitations and considerations in this release
217316-A Rev 00
• If a copper gigabit port is connected to a fast Ethernet port, then the link light
on the appliance does not light up. The
/info/host/link command shows
the actual status of the port.
Switch management
General
• When you save the configuration file to the backup file, the primary
configuration file is also saved. (Q00915233)
SNMP
• Because the SysOR MIB is not currently supported, a specific test to verify
that the agent properly handles unknown contextEngineID values fails when
executed. The following messages appear:
[FAILED] Remarks: get-request operation failed or had
errors
Received unexpected noSuchObject exception on get
operation
.
(Q00486049)
• Using some specific tests related to SNMPv3 compliance, you may
experience some issues. (Q00788702, Q00788718, Q00788728, Q00788722,
Q00788723)
Caution: SNMP community Index length of up to 10 characters and
SNMP community string length of up to 30 characters are currently
supported. (Q00899521)
Caution: The default community string “secret” for rwa user in Release
3.5 is no longer valid in Release 3.7.6. The default on Release 3.7.6 is
“public” and “private.”. (Q00895834)
Caution: If you connect to Device Manager and then remove or add a
management route before you close Device Manager, the connection to
the switch is lost. Nortel Networks strongly recommends closing Device
Manager before deleting or adding a route. (Q00907359)