Specifications

Application Views Stratacom ATM Application
Device Management Page 89 Cisco Stratacom BPX8600 and IGX8400
Tolerance, which specifies the maximum time
period for accumulated violations of cell-arrival
time parameters. This field applies to the First
Leaky bucket for cells with Cell Loss Priority of “0”
or “1.” The following configurations apply:
Units: microseconds
Applicable connection types: UBR, CBR, VBR,
ATFR, ABRSTD, ABRFST, ATFST
Defaults:
- CBR: 10000
- Others: 250000
Dependency: This object is not allowed for
BPX -> IPX atf/atfst connections.
CLP High
The Cell Loss Priority (CLP) tagging activation
threshold. The following configurations apply:
Units: % of VCQ Size
Applicable connections: ABRSTD, ABRFST,
ATFST
Default: 80%
Dependency: VSVD = enable (1)
Applicable cards: BXM, ASI-T3/E3
CLP Low
The Cell Loss Priority (CLP) tagging deactivation
threshold. The following configurations apply:
Units: % of VCQ Size
Applicable connections: ABRSTD, ABRFST,
ATFST
Default: 35%
Dependency: VSVD = enable (1)
Applicable cards: BXM, ASI-T3/E3
Other VC Queue
The other end maximum VC ( Virtual Circuit)
queue depth. The following configurations apply:
Units: cells
Applicable connection types: ATFR, ABRSTD,
ABRFST, ATFR, ATFST
Default:
- ATFR/ATFST: 1366
- Others: 16000
Dependency: VSVD = enable (1)
Applicable cards:
- ASI: T3/E3 only
ABR: 1-64000 cells
ATFR/ATFST: 1-1366 cells
- BXM: 0-64000 cells
Other EFCI Queue
The threshold setting used by the explicit
congestion notification feature for the other
endpoint’s transmit queue. The following
configurations apply:
Units: percentage