Specifications
Application Views StrataCom Application
Device Management Page 63 Cisco Stratacom BPX8600 and IGX8400
Rx Rate
The trunk receive rate in units of 1000 packets
per second.
Tx Capacity
The transmit capacity on this trunk in cells per
second.
Tx Load
The transmit load on this trunk in cells per
second.
Rx Capacity
The receive capacity on this trunk in cells per
second.
Rx Load
The receive load on this trunk in cells per second.
Trunk Type
The type of trunk. The values of trunk type
CBR(2), trunk type VBR(3), and trunk type ABR(4)
are writable for virtual trunks only. The trunk
type PHY(1) value is returned for a get-request on
a physical trunk.
VPI
The VPI (Virtual Path Identifier) used on this
virtual trunk. The maximum value is “255” for
DS3 trunks, and “63” for OC3 trunks. The
minimum value for set-request PDUs is “1.” This
value must be unique on a physical trunk port
and also must match the value for the path
through the ATM cloud.
Channels Reserv
The number of channels reserved for this trunk.
Traffic Class
The traffic classes of this trunk. Table 15 lists the
bit number and classes description.
Table 15: Traffic Classes
Bit Number Class Description
bit 0 Voice
bit 1 Time Stamped
bit 2 Non-Time
Stamped
bit 3 Frame Relay
bit 4 not used
bit 5 ForeSight
bit 6 ATM CBR
bit 7 ATM VBR
bit 8 ATM ABR