Specifications

Application Views StrataCom Application
Device Management Page 24 Cisco Stratacom BPX8600 and IGX8400
SEnet Gw Addr
The switch Ethernet interface gateway address.
SNet IPAddr
The switch network interface IP address.
SNet IPMask
The switch network interface IP address mask.
SNet Node Name
The switch network node name.
SNet Node Number
The switch network node number.
Domain Number
The switch network domain number.
Node Type
The switch network node type.
Alarm Status
The switch alarm status.
Prim Sw Revision
The switch primary software revision.
Sec Sw Revision
The switch secondary software revision.
Time Zone
The switch configured time zone.
Rebuild Status
This field is used by the INS to determine if the
switch shelf has experienced a rebuild. This field
also serves as the heartbeat mechanism.
Junction Node
The flag indicating whether the node is a junction
node.
VC Poll Rate
The VC (Virtual Circuit) polling rate (in minutes).
This system-wide field, which can be configured
via CLI command “cnfsysparm,” is used to specify
the period for the switch to poll connection
statistics.
SwitchShelf Slot Info
This view provides you with information that is
used to manage the switch shelf card cage
information. The table is indexed by slot. The
objects in this table can be grouped into five
catagories:
Card Y-redundancy information
Card status
Front card information
Back card information
Processor card-specific information
(applicable only to processor cards)